Gain Electronic Co Ltd 12BP12 ユーザーズマニュアル

ページ / 8
Follow the procedures below when finish operation 
1.  Press EMS button   
2.  Switch rotary key to “OFF” position   
3.  Remove rotary key and keep in a safe place 
4.  Remove batteries if not to be used for long period of time.
 
 
Transmitter LED Indicator 
Note: Switch rotary key to “OFF” position to turn off transmitter completely 
thus extend battery life, otherwise transmitter is in standby mode when 
rotary key remain in “ON” position. 
 
Changing Receiver Input Voltage 
If the factory preset receiver voltage is different from application, follow the 
procedures below to change input voltage.   
1.  Switch off receiver main power. 
2.  Remove the connector from original position. 
3.  Insert connector to new voltage position accordingly.   
 
 
Troubleshooting 
 
A.  When transmitter red LED flash fast continually, it may be 
1. One of pushbutton jammed. 
2. EMS button is not disengage 
3. Fail to follow Power-on procedures accordingly. 
 
B.  When transmitter red LED flash slowly, it may be low battery power. 
Green (Full Power) 
Operate as usual. 
Yellow (Mid Power) 
Unload the article as soon as possible and stop operation until 
new batteries are replaced. 
Red (Low Power) 
An EMS signal will be sent to receiver automatically to turn off 
receiver. To avoid the interruption during operation, check 