Mounting the Digital Repeater
The following diagrams illustrates the methods for mounting the repeater(s) in a typical wall or rack installation.
Brackets are provided for both options.
 Rack mount of the repeaters requires just two brackets mounted to the front corners of each module.  Note: the CSI digital repeaters
must be supported in the rack system with a shelf or slide rail. 
Do not rely on the brackets exclusively to support all the
weight of the modules.
Mount the Cross Band Coupler on the wall close enough
to the repeater modules to allow the RF jumpers to reach
from the CBC to the repeaters. The attachment system
used to anchor the CBC to the wall must be able to
support at lease 4.2 lbs / 1.9 kg.
The wall anchoring system you use for the repeaters
will need to be able to support at lease 19.6 lbs/ 8.9 kg
for each dual band module and 11.6 lbs/ 5.3 kg for
each single band add on module. The power supplies
are mounted approxamately as shown.
Interconnection of the repeaters in the rack mount configuration
requires the short RF Jumpers supplied with the CBC Module.
One will connect from the server port of the dual band module to
the 800MHz/1900MHz port on the CBC module.  The other will
connect from the server port on the single band module to the
700MHz port on the CBC module.
 Wall mount interconnection requires one connection
from the server port of the dual band module to the port
labeled “High” on the Cross Band Coupler.  The other will
connect from the server port on the single band module
to the port labeled “Low” on the CBC.