Section 4  Network Turnup Procedure
TRACER 6000 Series Integrated System Manual
 52
Copyright © 2005 ADTRAN, Inc.
612806420L1-1D
Instructions for Installing Network Modules
Individual access modules insert in the back of the chassis. Two phillips-head screws hold the modules in 
place for added security. To install network modules, follow the steps outlined below.
9.
CONNECTING THE MODULE INTERFACES
Quad T1 Module Interfaces
The physical T1 interfaces are provided using four RJ-45 ports located on the module. Straight-through T1 
interface cables can be used to interface to any standard T1 DTE device (not supplied).
Quad Ethernet Switch Module
The physical Ethernet interfaces are provided using four RJ-45 jacks. Ethernet cables are not supplied with 
your shipment. Connect any standard Ethernet device to one of the switch ports located on the rear of the 
unit.
Quad E1 (120
Ω
) Module Interfaces
The physical E1 interfaces are provided using four RJ-45 ports located on the module. Straight-through E1 
interface cables can be used to interface to any standard E1 DTE device (not supplied).
For proper airflow through the system to avoid elevated temperature levels, leave filler 
plates on any unused slots.
Instructions for Installing Network Modules
1.
Remove power from the unit.
2.
Remove the blank panel plate (if necessary).
3.
Slide the network module into the network slot until the module is firmly seated 
against the front of the chassis. 
4.
Secure the screws at both edges of the module.
5.
Install the optional hardware components (when necessary). For example, for 
the E1 network module, an optional BNC breakout panel is available.
6.
Connect the cables to the associated device(s).
7.
Restore power to the unit.
T1 crossover cables are needed when connecting two TRACER 64x0 T1 ports in 
back-to-back operation.
E1 crossover cables are needed when connecting two TRACER 64x0 E1 ports in 
back-to-back operation.