EXI ECO-Lite User Manual 
 
 
980-000004-000 
EXI Wireless Systems 
11 
May 2000 
  
Revision 
1.0 
 
11.  Operational Mode Change 
To change the operation mode: 
1. Enter Master Password 
2. Press ‘ENTER’ key 
3. Enter code for mode of operation: 
•  “51”   Test Mode 
•  “52” 
Normal Mode with Unlimited Alarm Duration 
•  “53’  
Normal Mode with Fixed Alarm Duration 
4. Press ‘ENTER’ key 
 
When the code is entered, the Controller will beep a distinctive number times for each different mode:  
 
•  Once for Test Mode 
•  Twice for Fixed Alarm Duration Mode and 
•  Three times for Unlimited Alarm Duration 
12. System Settings 
There are three modes of operation available to the user or installer: 
12.1.  Test Mode “51” 
In this mode the system does not generate any alarms. This mode is used to setup the field strength and 
position the controller properly. When a tag is in the field the controller will beep briefly.  Test mode 
will terminate after 30 seconds if the controller does not detect a tag in the field. 
12.2.  Normal Mode with fixed alarm duration “52” 
This is default operational mode in which the alarm will terminate after 20 seconds the tag is out of the 
field. 
12.3.  Normal Mode with unlimited alarm duration “53” 
In this mode the alarm will not end until the password is entered (system bypassed).