Murata Electronics North America DNT500P ユーザーズマニュアル

ページ / 9
DNT500 
 2008 by RF Monolithics,
 
Inc. 
50 
M-0500-0000 Rev D 
6. Demonstration Procedure 
The procedure below provides a quick demonstration of the DNT500 using a 
DNT500DK development kit: 
1.
 
Confirm that each DNT500P is installed correctly in an interface board, and that 
the U.FL jumpers between the DNT500P radios and the interface boards are in-
stalled. Also confirm that a dipole antenna is installed on each interface board, 
and that J14 has a jumper block installed on each interface board. See Figures 
5.4.1, 5.4.2 and 5.4.3 above. 
2.
 
Attach each transceiver/interface board to a computer with the DNT500 Wizard 
utility program installed. Place the transceivers at least 3 feet (one meter) apart. 
3.
 
Start the DNT500 Wizard utility program on both computers. 
4.
 
On each computer, press the Connect button on the Wizard window. This will 
open a serial port setup dialog box. Set the baud rate to 115.2 kb/s and select the 
COM port the DNT500 is connected to. Parameter values on the left of the Wiz-
ard main window and on the Transceiver Setup tab will fill in. 
5.
 
Select the RF Test tab on the Wizard. A message placed in the Transmit Window 
is sent to the specified MAC address each time the Apply button is pressed. Mes-
sages received are displayed in the lower text box. The receive message text box 
can be cleared with the Clear button.