When the data rate is set to 500 kb/s, the firmware interlocks the transmit power level to 19 dBm (85 mW) 
or less to comply with FCC regulations. 
JoinPremit
 - valid parameter on a base only. Controls whether remote nodes are permitted to join the 
base. Parameter values are 0 = no joining permitted, 1 = remotes only may join, 2 = remotes or routers 
may join (future function). 
UserTag
 - this is a user definable field intended for use as a location description or other identifying tag 
such as a “friendly name”. 
4.2.2 Bank 1 - System Settings 
 
01 
00 
FrequencyBand 
R/W 
0.. 1 
01 
01 
AccessMode 
R/W 
0..4 
01 
02 
BaseSlotSize 
R/W 
6..233 
01 
03 
LeasePeriod 
R/W 
0..250 
01 
04 
ARQ_Mode 
R/W 
0.. 1 
01 
05 
ARQ_AttemptLimit 
R/W 
0..63 
01 
06 
TDMA_MaxSlots 
R/W 
0..15 
01 
07 
CSMA_Predelaty 
R/W
 
0..255 
01 
08 
CSMA_MaxBackoff 
R/W 
0..255 
01 
09 
MaxPropDelay 
R/W 
0..255 
01 
0A 
EpochMode 
R/W 
0..2 
01 
0B 
CSMA_RemtSlotSize 
R/W
 
1 ..255 
01 
0C 
CSMA_BusyThreshold  R/W 
1..255 
01 
0D 
RangingInterval 
R/W
 
0..255 
 
FrequencyBand
 - this parameter sets the range of frequencies over which the radio will operate. Two 
settings are defined: North America (902-928 MHz) and Australia-New Zealand (915-928 MHz). 
AccessMode
 - this sets the channel access mode that remotes will use to communicate with the base: 
Access Mode 
Description 
Max # of Remotes 
Remote Slot Size 
CSMA polling 
1024 
manual 
CSMA contention 
1024 
manual 
2 (default) 
TDMA dynamic slots 
up to 16 
automatic 
TDMA fixed slots 
up to 16 
automatic 
TDMA with PTT 
1024 
automatic 
BaseSlotSize
 - This parameter set the maximum number of bytes allocated to user messages and their 
RF headers. This value must be set by the user for all access modes (default value is 20 bytes). 
LeasePeriod - 
this sets the duration in seconds for network address leases that remotes may receive 
from the base. If a period of zero is specified, then lease and network address functions are disabled. The 
minimum valid lease period is two seconds. Remotes will attempt to renew their leases at an interval 
equal to half the lease period. For example, if the lease period is set to four seconds, remotes will renew 
their leases every two seconds. 
ARQ_Mode - 
this sets the ARQ mode for delivery of application messages. In ARQ mode, an ACK is 
expected from the receiving radio for each message addressed and sent to it. If no ACK is received, up to 
ARQ_AttemptLimit,
 efforts to send the data will be made, after which the message is discarded. In redun-
dant broadcast mode, each broadcast message is sent exactly ARQ_AttemptLimit times. No ACKS are 
sent or expected. The following bit options control this function: 
Size in 
Bank Loc'n 
Name 
R/W 
bytes Range Default; Options 
 
 
0x00 = North America; 
0x01 = Australia, 0xFF = auto 
2 = TDMA Dynamic Slots 
20 bytes 
5 s (0 to disable) 
0 = ARQ, 1 = redundant broadcast 
5 attempts 
8 slots 
0x03 
0x0A 
0x0D (3.8 mi, 6 km) 
0 = use previous; 1 = increment 
2 = random 
50 
20 
0
 (disable)