Proxim Wireless Corporation XB92WFR ユーザーズマニュアル

ページ / 336
Advanced Configuration
Tsunami
®
 800 & 8000 Series - Software Management Guide 
113
After configuring the required MIMO parameters, click OK and then COMMIT.
5.4.3.4 Frequency Filter
The  Frequency Filter tab allows you to configure the lower and upper frequency band edges, which helps to limit the
available frequency band, for a given frequency domain, to a smaller band. By limiting the frequency band, the time taken by
a device to scan and connect to any other device in the network is reduced. The Frequency Filter Configuration screen
appears as shown below.
Figure 5-43 Frequency Filter Configuration
The frequency range limit for the filter lower and upper edge is 0 - 10000 MHz; by default, the lower frequency edge is set to
0 MHz and the upper frequency edge is set to 10000 MHz. Configure the values and Click OK and then COMMIT.
Guard Interval
Guard Interval determines the space between symbols being transmitted. The guard 
interval can be configured as either Short GI - 400n seconds or Full GI-800n seconds.
In 802.11 standards, when 40 MHz Channel Bandwidth is configured then Short GI can be 
used to improve the overall performance and throughout.
By default, Full GI is enabled for 5 MHz, 10 MHz and 20 MHz channels.
Short GI-400 nSec is valid only for 40 MHz channel bandwidth
Short GI-400 nSec is not valid for 82x devices.
Rx Antennas Status
Allows the user to select the antenna(s) for receiving data. Select the check-box against 
each antenna(s) for receiving data and click OK.
: Atleast two Rx antenna ports should be enabled when data stream is dual or 
auto.
Parameter
Description