Nortek Security & Control LLC/GTO Access GDKPD318B ユーザーズマニュアル

ページ / 1
Copyright © GTO Access Systems 2015                                          10007727
 
 CSKPL
 DIGITAL KEYPAD 
 TRANSMITTER
  Installation Instructions
DESCRIPTION
This Digital Keypad is designed for use with automatic garage door 
operators. The radio format provides unparalleled security with more than 
a million different codes.
To activate the door operator, the user enters their unique 1 to 6 digit long 
code on the unit’s keypad and presses the 
START/STOP button. For up to 30 
seconds after the last activation, the keypad can be re-triggered by simply 
pressing the 
START/STOP button again. This allows the user to stop or 
reverse the opener quickly, without having to re-enter their code.
The keypad has built-in lighting for use at night or in dark areas. The clear 
silicone keys are backlit with a pleasing blue glow. By pressing the 
START/
STOP button first, before entering their code, the user can light up the 
keypad.  Pressing the 
START/STOP button twice at any time will light up 
the keypad.
The keypad lockout timer will disable the keypad after 10 activations. The 
keypad must remain idle for 30 seconds before new attempts.
The garage door operator contains a built-in receiver that is programmed by 
sending a signal from the user’s transmitters. This stores the transmitter’s 
code into the receiver’s memory. The receiver will retain its memory even 
without power and will only activate from these “memorized” transmitters. 
Each keypad code can be considered a different transmitter.
KEYPAD COMPONENTS
KEYPAD FEATURES
KEYPAD OPERATION
CHANGING BATTERIES
LIMITED WARRANTY
FCC STATEMENT
PROGRAMMING OPERATOR
   
 
        WALL MOUNTING
PRINTER’S INSTR
UCTIONS:
INSTR,INSTL,MDTK,PVT LBL - GTO P/N:
 10007727
 - INK:
 BLACK - MA
TERIAL:
 20 LB.
 MEAD BOND - SIZE:
 11.000”
 X 8.500”
 - SCALE:
 1-1
www.mightymule.com
ADDING A KEYPAD CODE
1
PRESS THE OPERATOR'S LEARN 
BUTTON FOR 1 SECOND AND RELEASE.
 
THE OPERATOR SHOULD BEEP AND THE 
LIGHT SHOULD BLINK ONCE.
 
THE RED LED WILL REMAIN LIT (LEARN 
REMOTE MODE).
2
WHILE THE RED LED IS ON, 
ENTER A 1-6 DIGIT KEYPAD CODE 
THEN PRESS AND HOLD THE KEYPAD'S 
START/STOP KEY UNTIL THE OPERATOR 
BEEPS AND THE LIGHT BLINKS ONCE.
3
REPEAT STEPS 1 & 2 FOR ANY
 ADDITIONAL KEYPAD CODES
W
X
G
H
I
D
E
F
AB
J
K
L
M
N
O
R
S
T
U
V
SCREW
PLUGS
SCREW
ANCHORS
MOUNTING
SCREWS
KEYPAD
HINGED COVER
PROTECTS THE 
KEYPAD
SOFT BLUE LIGHTS
ILLUMINATE THE KEYS
FOR NIGHTTIME USE
START/STOP BUTTON STAYS ACTIVE FOR
30 SECONDS AFTER A CODE IS USED SO THE 
OPENER CAN BE STOPPED OR REVERSED
NOTE: FOR SECURITY, THE KEYPAD WILL SHUTDOWN
AFTER 10 CODE ENTRIES UNTIL IT IS IDLE FOR 30 SECONDS
TEN KEYS ENTERING 
1-6 KEYPAD CODES
USING NUMBERS OR LETTERS
 
MOUNT THE KEYPAD IN
CLEAR VIEW OF THE DOOR
WITH THE TWO SCREWS SUPPLIED
USE THE SCREWS 
ANCHORS SUPPLIED
IF REQUIRED
SCREWS 
ANCHORS
PUSH IN THE
TWO SCREW
COVER TO HIDE
THE SCREWS
DAYTIME OPERATION
START
STOP
START
STOP
START
STOP
1
2
PRESS START/STOP (LIGHTS KEYPAD) 
1
2
3
NIGHTTIME OPERATION
PRESS THE LIGHT (      ) BUTTON TO TURN THE OPERATOR’S LIGHT ON/OFF
(KEYPAD MUST HAVE AT LEAST ONE CODE PROGRAMMED INTO THE OPERATOR)
1
LIGHT OPERATION
1-6 DIGIT KEYPAD CODE THAT
WAS ENTERED INTO OPENER
ENTER THE KEYPAD CODE
PRESS START/STOP
ENTER THE KEYPAD CODE
PRESS START/STOP 
1-6 DIGIT KEYPAD CODE THAT
WAS ENTERED INTO OPENER
NOTE: TO STOP OR REVERSE THE OPERATOR, THE START/STOP BUTTON CAN BE 
PRESSED AGAIN FOR UP TO 30 SECONDS WITHOUT RE-ENTERING THE CODE.
 
 
1
3
4
2
REMOVE THE TWO
SCREWS AND SLIDE
THE BATTERY COVER OFF 
 
 
REMOVE THE 
LOW VOLTAGE
BATTERIES AND 
DISPOSE OF THEM 
PROPERLY
INSTALL 3 FRESH
AAA BATERIES
 
 
 
 
BE SURE THE 
SILICONE GASKET
IS IN PLACE
 
REPLACE THE
BATTERY COVER
AND RE-INSTALL 
THE TWO SCREWS
 
 
 
 
This device complies with part 15 of the FCC Rules. Operation is subject to the following 
two conditions: (1) This device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation.
 
NOTE: This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide rea-
sonable protection against harmful interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, which can 
be determined by turning the equipment off and on, the user is encouraged to try to correct 
the interference by one or more of the following measures:
 
•   Reorient or relocate the receiving antenna.
•   Increase the separation between the equipment and receiver.
•   Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected.
•   Consult the dealer or an experienced radio/TV technician for help.
CAUTION!
Any changes or modifications not expressly approved by the party responsible for compli-
ance could void the user’s authority to operate the equipment.
This product is warranted to the original consumer against defects in material and workmanship 
for the periods mentioned above. GTO Access Systems will repair, or at its option, replace, any 
device that it finds requires service under this warranty. This warranty does not apply to damage 
to the product from negligence, abuse, abnormal usage, misuse, accidents, normal wear or tear 
or due to failure to follow Seller’s instructions, or arising from improper installation, storage or 
maintenance. In no event will GTO Access Systems be responsible for incidental, compensatory, 
punitive, consequential, indirect, special or other damages. The remedies provided by this 
warranty are exclusive. Some states do not allow the exclusion or limitation of incidental 
and consequential damages, so the above limitation or exclusion may not apply to you. Any 
warranties implied by law are limited to the time periods set forth above. Some states do not 
allow limitations on how long an implied warranty lasts, so the above limitation may not apply 
to you. This warranty gives you specific legal rights, and you may also have other rights which 
vary from state to state.
For warranty service, contact GTO Access Systems at 800-543-1236. In order to be protected by 
this warranty, save your proof of purchase should repair be required.
IMPORTANT!
Radio controls provide a reliable communications link and fill an important need in portable 
wireless signaling. However, there are some limitations which must be observed.
•  For U.S. installations only: The radios are required to comply with FCC Rules and 
Regulations as Part 15 devices. As such, they have limited transmitter power and therefore 
limited range.
•  A receiver cannot respond to more than one transmitted signal at a time and may be 
blocked by radio signals that occur on or near their operating frequencies.
•  Changes or modifications to the device may void FCC compliance.
•  Infrequently used radio links should be tested regularly to protect against undetected 
interference or fault.
•  A general knowledge of radio and its vagaries should be gained prior to acting as a 
wholesale distributor or dealer, and these facts should be communicated to the ultimate 
users.