ZyXEL Communications Corporation 5VZ-A2011 ユーザーズマニュアル

ページ / 404
Chapter 16 Quality of Service (QoS)
CellPipe 7130 RG User’s Guide
232
16.6.1  Policer Setup Edit
Click the Add button or the Edit icon in the Policer Setup screen to configure a 
classifier.
Figure 93   Add/Edit Policer Setup 
The following table describes the labels in this screen. 
Table 74   Add/Edit Policer Setup
LABEL
DESCRIPTION
Active
Select the check box to enable the policy.
Name
Enter a descriptive name of up to 15 printable English keyboard 
characters, including spaces.
Meter Type
This is set to Simple Token Bucket, which uses tokens in a bucket to 
control when traffic can be transmitted. The bucket is a buffer that 
temporarily stores outgoing packets and transmits them at an average 
rate.
Committed 
Rate
Enter the maximum committed rate for the class/es.
Committed 
Burst Size
Enter the the maximum committed burst size for the class/es.
Available Class
This shows all the classes created in the CellPipe 7130 RG. Select the 
class that you want to include in the policy and click Add to move it to 
selected class.
Selected Class
This shows to which classes the policy applies. Select the class that 
you want to exclude from the policy and click Remove to move it to 
the available class.
Add/Remove
Use these buttons to add or remove a class from either Available Class 
and Selected Class boxes.