165E5733-00 Rev. 03 
6.  SYSTEM INTERFACE WIRING 
6.1  General 
All wire types and installation practices must comply with the requirements for the aircraft. Unless 
otherwise noted, minimum wire size is 22 AWG for standard copper wire or 24 AWG for high-strength 
copper alloy wire. 
Terminate all shields at ground block or ground stud on SDU tray. Keep shield drains and unshielded 
conductor lengths as short as practicable (<3”). 
6.2  Primary Power, Antenna, and SCM 
The primary power, antenna, and SCM connections in Figure 6-1 are required for all Iridium SATCOM 
System installations. The system will start, and continue to operate, whenever power (20.5 – 32.2 VDC) 
is available at the Primary Power Input pin (J1C-2). 
 
Figure 6-1 – Primary Power, Antenna, and SCM Interface