IPM Healthcare Ltd. IFG-PCU02 ユーザーズマニュアル

ページ / 45
Other status indication)  
 
•  Ensure battery is inserted 
on the mat.  
Error codes 
(indicated on 
Smart 
Phone/
Parent 
Control Unit
)
 
Possible cause 
Remedy 
E1 
•  The fiber sensor is broken 
 
•  Mat is no longer 
functioning. Please 
contact your service 
center. 
E8 
•  High pressure, such as heavy 
weight on the mat or the 
Baby sitting up.  
•  If the indication remains 
when the Baby is in 
sleeping position, the 
Baby weight had 
exceeded the defined 
weight limit of the mat. 
E9 
•  Device Malfunction 
•  Please contact your 
service center 
13. MAINTENANCE  
•  DO NOT subject the mat to sharp folds as it may damage the sensing element and affect the functionality and 
sensitivity of the mat.  
 
•  DO NOT wash or immerse the whole mat in water. Clean the mat with a soft damp cloth and allow to dry. 
Avoid using any chemical or cleaning detergent.  
 
•  Keep your mat away from sources of moisture. It may cause the electronic control circuit to malfunction.  
 
•  DO  NOT  drop  the 
Parent  Control  Unit
  on  the  floor  as  it  may  damage  internal  components  and  cause 
malfunction. 
 
•  Keep the 
Parent Control Unit
 away from moisture.  
 
•  Remove batteries from the 
Parent Control Unit
 and mat when not in use for a long period of time.  
 
•  The operating temperature range for the 
Intelligent Infant Cradle Mat (Active Baby Monitor) 
is from 
10
0
C ‐ 
40
0
C
DO NOT operate beyond this range as it may not function according to defined specifications.   
14. TECHNICAL SUPPORT 
Before you contact the Technical support, please read the Troubleshooting and FAQ section. 
 
If you have questions about the use or features of the product please contact our Call Center at the following e‐mail address: support@ipmhc.com. 
 
When you call or contact us for support, please include as much information possible from the packaging material. This will help us in speeding the 
process.