5.3.2 Pre-acquisition commands
¾ Press the
button to start calibrating the processing parameters used
on the acquired data.
¾ Push the trolley a few meters then press the
button to save the
parameters (see Fig. 5-5).
Fig. 5-5 – Start calibration
!
NOTE
Calibration can be repeated as often as required during a survey. It is most
useful whenever the ground conditions change, i.e. from asphalt to concrete, or
from concrete to grass.
useful whenever the ground conditions change, i.e. from asphalt to concrete, or
from concrete to grass.
¾ Press the
button to avoid performing the gain calculations. If you
skip calibration, you can only view pre-existing radar maps.
¾ The spy lights representing the radar (RADAR), battery (BATT), acquisition speed
(SPEED) and acquired sweeps (SWEEP) indicate the current activity status of the
system:
system:
.
¾ Press the color scale button to select the desired palette for viewing radar maps:
¾ Zoom in on the maps up to a magnification of 4X by selecting one of these buttons:
¾ Press the
button to shut down the software.