Charles Machine Works Inc The 2150GR250 ユーザーズマニュアル

ページ / 39
2150GR Ground Penetrating Radar 
054-139 - Rev. 1
 
 
29/36 
5.4 Error messages 
Error messages found in the program are listed below (in italics) followed by their solutions: 
 
¾  Network error. Retry or check hardware! 
Check that the network cable is connected properly to the PC and the control unit. Try 
restarting the program. 
 
¾  New depth must be > 0. Please insert new value to continue 
¾  New depth must be > 0. Unable to set the depth 
¾  New depth missing. Please insert value to continue 
Select a new value for the depth of the identified pipe. 
¾  Warning. Unable to print on the selected printer 
Check that the printer is switched on and connected to the computer. 
 
¾  Unable to review: calibration file has been lost. 
The calibration files for the selected survey have been deleted. To be able to see the data, the 
Igr.bkg and Igr.stc files have to be copied from the main program directory (C:\2150GR) 
into the survey directory. 
¾  Unable to review: mark file has been lost 
A system file has been deleted, making it impossible to review the selected acquisition. 
 
¾  Unable to mark: marker already present at this distance! 
You have tried to insert a pipe in a point already containing one; select a new point. 
 
¾  Gain calibration has been skipped (or lost). Calibrate gain to proceed. 
¾  Unavailable: gain calibration has been skipped (or lost). 
¾  Unavailable: gain calibration has changed. 
A calibration has to be performed to be able to acquire data. See Paragraph 5.3.2. for 
calibration instructions. 
 
¾  Unavailable: directory has been lost. 
The last acquisition cannot be recovered, select a new acquisition.