5.3.6 Depth calibration
¾ Press the
button to open a window where you can enter the exact
depth of the pipe or cable (if it is known) from another source such, as technical
maps or from opening manhole covers.
maps or from opening manhole covers.
¾ Otherwise, press the
button to activate the following window,
Select the correct propagation speed by using the
and
buttons to
adjust the white-line curve to the shape of the hyperbola.
!
NOTE
In both cases, you have to select one of the icons shown in the Marker window
to confirm the depth of the identified pipe. This operation can be repeated
several times during the acquisition: a symbol will appear at calibration points
describing the type of the characteristics of the detected pipe.
to confirm the depth of the identified pipe. This operation can be repeated
several times during the acquisition: a symbol will appear at calibration points
describing the type of the characteristics of the detected pipe.
¾ Press the
button to finish the scan while remaining in the open survey.
¾ Press the
button to save the scan file onto the computer hard disk (in the
C:\2150GR\Mission directory). Continue the same scan by moving the trolley in the
original direction.
original direction.
¾ Press the
button to finish the scan and go back to the Main Menu andto