Charles Machine Works Inc The 2150GRDUO ユーザーズマニュアル

ページ / 43
2150GR Ground Penetrating Radar 
054-140 - Rev. 2
 
 
6/36 
3.1.1 The 2150GR Control Unit 
The control unit has the following main functions: 
•  To communicate with the antenna 
•  To communicate with the notebook computer 
•  To pilot the position sensor 
The control unit is fitted with the following connection ports: 
¾  Power supply port (1): the power supply cable connects the battery to the Control 
Unit. The port is marked BATTERY.  The blue indicator (5) lights when the 
system is on, or when the system is powered by the battery. 
¾  Network port (2): the inverted network cable connects the control unit to the 
notebook PC. This port is marked LAN. 
¾  Antenna port (3): the antenna-control unit cable connects the Control Unit to the 
antenna. This port is marked ANT. 1. 
¾  Position sensor port (4): the position sensor is connected to the control unit using 
the cable already installed on the trolley (not shown). This port is marked 
WHEEL. 
¾   On button (6): Press the on button (6) to start the system.  The blue indicator (5) 
lights when the system is on, or when the system is powered by the battery. 
      
     
 
Control Unit 
 
Antenna-Control Unit 
Connection Cable  
 
Inverted Network Cable  
 
Power Supply Cable