Risco Ltd. RK350DT ユーザーズマニュアル
4
Terminal
Description
+ -
+12 VDC, - GND
ALARM YEL GRN
N.C alarm relay
YEL / GRN (RISCO BUS)
NOTE: As defined by DIP SW 6
TAMPER +-
N.C tamper switch
AM +-
N.C anti mask alarm relay
LED ENABLE
Used to remotely control the LEDs when DIP1 is set to ON
Enable: input is +12V OR no terminal connection
Disable: Connect the input to 0V
This feature prevents an intruder from gaining knowledge of the
detector’s status and disables anti-mask detection.
Enable: input is +12V OR no terminal connection
Disable: Connect the input to 0V
This feature prevents an intruder from gaining knowledge of the
detector’s status and disables anti-mask detection.
SET / UNSET
This input enables controlling anti-masking operation in accordance to the
system status, Set (Arm) / Unset (Disarm).
system status, Set (Arm) / Unset (Disarm).
System Status
Input Status
AM Relay
Set (Arm)
0V
Off
Unset (Disarm)
12V or no connection
On*
* DIP SW 4 is ON (Anti mask enabled)
NOTE: Make sure that jumper J5 is installed to bypass the Swivel Tamper.
Step 5b: Setting DIP Switch Settings (Standalone Mode)
Set the DIP switch settings according to the table, below:
DIP
SW
SW
Description
Def.
Def. Status
1*
LEDs: ON: Enable / OFF: Disable
ON
LEDs ON
2*
Sensitivity (PIR)
Low
Mid.
Norm.
Max.
ON
Normal
OFF
OFF
ON
ON
3*
OFF
ON
OFF
ON
OFF
4*
Anti Masking: ON: Enable / OFF: Disable
ON
Enable
5*
High Sensitivity (Anti Mask): ON: High /OFF: Low
OFF
Low
6
Mode: ON: BUS / OFF: Relay (see Defining BUS ID)
OFF
Relay
Relay mode
DIP SW 7
DIP SW 8
DIP SW 9
DIP SW 10
Normal
OFF
OFF
OFF
OFF
DEOL
ON
ON
OFF
OFF
TEOL
ON
ON
ON
ON
NOTES:
1. For DEOL DIP switches 7 and 8 should both be ON.
2. For TEOL DIP switch 7-10 should be ON.
MIN MAX
Adjust microwave coverage area by using the trimmer on the PCB.