Lutron Electronics Company Inc 0027 ユーザーズマニュアル

ページ / 8
1
P R E L I M I N A R Y — N O T   F O R   R E L E A S E
Please Read Before Installing
System Bridging Timeclock
TM
RA-SBT, RB-SBT
120/127 V    50/60 Hz (18 V    / 0.3 A adapter)
Installation Instructions
Overview
The System Bridging Timeclock (SBT) bridges two
RadioRA systems, providing a total of 64 Zone Controls
and 24 Master Controls. The SBT also provides an 
RS-232 interface, contact closure inputs, and an astro-
nomic time clock.
Each SBT covers approximately 2500 square ft. 
(232 m
2
) of living space.
Up to 3 RF Signal Repeaters may be used with the SBT
for each system to extend the communications range.
Important Notes
Codes: Install in accordance with all local and
national electrical codes.
Power: Use only the adapter provided by Lutron with
the SBT.
Caution - Using an adapter not rated for
the following specifications could damage
the SBT and possibly overheat the adapter.
• Input: 120/127 V    50/60Hz
• Output: 18 V   / 0.3 A Class 2
Environment: Ambient operating temperature: 
0-40°C, 32-104°F, 0-90% humidity, non-condensing.
Indoor use only.
Cleaning: To clean, wipe with a clean damp cloth.
DO NOT use any chemical solutions. Do not paint
the SBT.
Mounting: DO NOT ground the SBT. DO NOT
mount the SBT in a metal enclosure.
RF Device Placement: Master Controls and Zone
Controls that are to be controlled by the SBT must
be located within 30 ft. (9 m) of the SBT or an RF
Signal Repeater. 
Setup: The SBT will not function until it is addressed
and programmed. See the System Bridging
Timeclock 
Setup and Programming Guide.
RA-SBT
RB-SBT