Lutron Electronics Company Inc 0055 ユーザーズマニュアル

ページ / 1
Install in accordance with all local and 
national electrical codes.
Caution! These controls 
must not be used to control 
equipment that is not visible 
from every control location. They must 
also not be used to control equipment 
that could create hazardous situations 
such as entrapment if operated 
accidentally. Examples of such 
equipment which must not be operated 
by these controls include (but are not 
limited to) industrial doors, microwave 
ovens, heating pads, etc. It is the 
installer’s responsibility to ensure that 
the equipment being controlled is visible 
from every control location and that 
only suitable equipment is connected to 
these controls.
Environment: Ambient operating 
temperature: 32 to 104 °F (0 to 40 °C),  
0 to 90% humidity, non-condensing. 
Indoor use only.
Spacing: If mounting one control above 
another, leave at least 4½ in. (114 mm) 
vertical space between them.
Faceplates: Use Lutron Stanza 
faceplates for best color match and 
aesthetic appearance. Do not paint 
controls or faceplates.
Cleaning: To clean, wipe with a clean 
damp cloth. 
Do not use any chemical 
cleaning solutions.
Wallboxes: Lutron recommends using 
3.5 in. (89 mm) deep wallboxes for 
easier installation.
RF Device Placement: RF keypads 
must be located within 20 feet (6 m) 
of an RF signal repeater or a device 
configured as a repeater.
Stanza RF keypads cannot control 
any device in the system until they are 
addressed and programmed. When 
powered and unaddressed, they turn 
on their button backlights to indicate 
proper operation.
Installation
Caution! Locate and remove 
fuse or lock circuit breaker in 
the OFF position before pro-
ceeding. Wiring with power ON 
may result in personal injury or 
death.
1.  Turn power OFF at fusebox or circuit 
breaker.
2.  Prepare wires. When making 
wire connections, follow the 
recommended strip lengths and 
combinations for the supplied wire 
connector.  
Note: Wire connectors provided are 
suitable for copper wire only.
   Wire Connector:
•  Strip insulation 3/8 in. (9.5 mm) for #14 
AWG (1.5 mm
2
) wire
•  Strip insulation 1/2 in. (12.7 mm) for 
#16 or 18 AWG (1.0 mm
2
 or 0.75 mm
2
wire
Twist wire connector tight.
3.  Wire controls as follows:
  a.  Connect the black control wire to 
the Hot/Live wire coming from the 
panel.
  b.  Connect the white control wire to 
the Neutral wire coming from the 
panel.
4.  Push all wires back into the wallbox 
and 
loosely fasten the control to the 
wallbox using the control mounting 
screws provided. Do not pinch the 
wires.
5.  Attach Lutron Stanza faceplate 
adapter and faceplate. 
  a.  Install faceplate adapter onto front 
of control(s).
  b.  Tighten control mounting screws 
until faceplate adapter is flush to 
wall (do not over-tighten).
  c.  Snap faceplate onto faceplate 
adapter, and verify that control is 
aligned properly.
  d.  If control(s) is (are) misaligned, 
loosen mounting screws 
appropriately. 
6.  Restore power. Check for correct 
local operation (see Operation). 
Keypad will not control a remote 
device until it is addressed.
operation
Installation Instructions
Please Read Before Installing
Stanza
TM
Stanza
tM
 Keypads
SZ-2B, SZ-3B,
SZ-4B, SZ-5B,
SZ-3/1B
120 V   50 / 60 Hz  0.5 W
Important notes
SZ-3B
Mounting Diagram
Control 
mounting 
screws
Wallbox
Control
Included:
Wire Connectors (2)
Mounting Screws (2)
Faceplate 
adapter 
mounting 
screws
Faceplate/adapter purchased 
separately.
SZ-2B
SZ-4B
SZ-5B
SZ-3/1B
Black
White
Hot/ 
Live
Neutral
120 V
50 / 60 Hz
Status LEDs
Indicate current 
scene selected; 
all glow softly 
as night lights 
when scene is not 
selected
Keypad Buttons
Can be programmed to control one or 
more zones or contact closure outputs 
Buttons are backlit for easy location in 
a darkened room.
   Returning the Dimmer/Switch to 
Factory Settings
1.  Triple-tap a button on the keypad 
quickly (within 1 second).
2.  Press and hold the same button on 
the keypad for 5 seconds (until the 
status LEDs flash) .
3.  Triple-tap the same button on the 
keypad quickly again.
  Notes
•  Returning to factory settings will clear 
all programming from the keypad, and 
will prevent it from being controlled 
over RF.
•  After being returned to factory 
defaults, the device will need to be re-
addressed as part of a system.
troubleshooting Guide
Symptom
Cause and Action
Keypad LEDs do not 
light
Power not present
•  Circuit breaker OFF or tripped. Perform short circuit check.
Wiring error
•   Check wiring to be sure it agrees with installation instructions 
and wiring diagrams.
Lights do not respond 
to a button press
Improper programming
•  Check programming in the Stanza software.
Out of RF range
•  Ensure device is within 20 feet (6 m) of another device 
configured as a repeater.
All status LEDs flash 
when each keypad 
button is pressed
Keypad is not addressed to the system
•  Address device as part of a Stanza system.
Lutron Electronics Co., Inc.
Made and printed in the U.S.A.
P/N 030-995 Rev. A 6 /08
technical support:  USA, Canada, Caribbean: 1.800.523.9466 
Mexico: +1.888.235.2910 
Central/South America: +1.610.282.6701
Warranty: 1-year limited warranty standard. 2-year parts and labor warranty, with 
8-year pro-rated parts replacement on commissioned systems.
These products may be covered under one or more of the following U.S. patents: 5,248,919; 
5,637,930; 5,838,226; 5,848,054; 5,905,442; 6,687,487; 6,803,728; and corresponding foreign 
patents. U.S. and foreign patents pending. Lutron and the sunburst logo are registered 
trademarks and FASS and Stanza are trademarks of Lutron Electronics Co., Inc.
© 2008 Lutron Electronics Co., Inc.
R
FCC Information
Note: This equipment has been tested and found to comply with 
the limits for a Class B digital device pursuant to Part 15 of the 
FCC rules. Operation is subject to the following: (1) This device 
may not cause harmul interference, and (2) this device must 
accept any interference received, incouding interference that 
may cause undesired operation.