Model 950/960 Proximity Reader
An external device can be connected to all LEDs and the beeper at the
14-position terminal block TB1 inside the interface unit. In this case,
the LEDs and beeper can be driven by the reader or the external
device. Driving the appropriate TB1 position to a low voltage
activates the indicator. This low voltage can be sensed by the external
device even when the indicator is driven by the reader.
Supervised F/2F Mode Operation:
In the supervised modes, the
reader sends badge data or reader status data to the microcontroller
approximately once every second and waits for an acknowledgment from
the microcontroller. The reader continues sending the data every second
until an acknowledgment is received. If an acknowledgment is not
received after the third attempt, the reader stops reading badges, the red
LED starts flashing slowly (every 2 seconds), and a short, triple beep
sounds every 30 seconds, unless silent supervised mode is selected. Once
the reader receives an acknowledgment, it begins reading badges again,
the beeper stops sounding, and the red LED stops flashing.
Badge Read Operation:
Each time the reader sends badge data, the
yellow LED blinks off briefly, and the beeper sounds.
Reader Tamper Operation:
The Model 950/960 Readers incorporate a
tamper switch inside the interface unit. An additional installer-supplied
tamper switch may also be connected to TB1. While the door on the inter-
face unit is open, all badge reading functions are disabled; and a tamper
condition is indicated by a triple beep every 30 seconds. In the Wiegand
and F/2F modes, the red LED stays on continuously during a tamper
condition (this can be sensed by a low voltage on TB1 position 3). In both
supervised modes, the red LED flashes fast (every 400 ms) and all
communications with the microcontroller are suspended, taking the
reader offline.
Door Contact and Exit Request Inputs:
The Models 950 and 960
Readers have a normally closed door contact switch input and a normally
open exit request switch input on TB1. In the supervised modes, the state
of both switch inputs is periodically reported to the microcontroller, but
changes to switch inputs are reported immediately. In the Wiegand and
F/2F modes, these switch inputs have no function.