Bar codes that are shorter than the sum of the Postamble trimming and 
Preamble trimming will be transmitted without trimming. Selective trimming 
and min/max bar code data is also supported through Postamble specifications, 
(See Preamble above for complete details). 
Characters 
This setup option allows you to output ASCII characters different from the 
ones scanned.  (Don't use this option to configure the Radio/Freedom Reader 
for your non-US keyboard -- instead, use the Keyboard Country option 
described below.) 
 
For example: Suppose you want the Radio/Freedom Reader to output a hex 
92 character every time you scan a 1 (hex 31); you want to remap hex 31 to 
hex 92, (If you're using 8 data bits, output of 80-F8 codes is possible.) 
 
  1) Scan the Start Setup Bar Code 
  2) Scan the Characters Bar Code on the Setup Sheet. 
  3) Scan 3 1 and 9 2 to output hex 92 when reading a "1". 
  4) Scan up to 7 other pairs of character reassignments. 
  5) Scan Set when complete.  
  6) Scan End Setup to exit setup mode. 
 
Hex values for each character code are shown on the Full ASCII Menu, (the 
back of Wireless Setup Menu). The equivalent decimal values are also shown 
for each character. 
 
You can also eliminate characters by reassigning hex codes to FF.  For 
example, to strip all $ (dollar sign) characters from transmission, you would 
follow the above instructions and scan 2  4  F  F in step 3. 
 
Keyboard country 
This option configures the Radio/Freedom Reader for your choice of 15 
keyboard country settings, such as USA (the default), UK, French, German, etc. 
 
Scan the keyboard country bar code and then the two-digit code for your 
keyboard country (listed on the Reader Setup Menu), such as 14 for UK. 
 
Set ID Character 
The ID is used to differentiate between multiple RF Lasers attached to the 
same Base Station.  
  
Multiple scanners on one base station require each scanner to be set to a 
unique ID of 0,1,2,3.....9. Scan Set ID Character and then scan 0-9 for each 