Worthdata Inc LZ400RF ユーザーズマニュアル
3
Installation
Components of RF Laser Readers
In the event the shipping box shows damage on arrival, please note the
damage on the carrier's receipt log.
The supposed contents of your Reader shipment is the following:
1. An R/F Base Station with 1-10 RF Lasers.
2. A Worth Data regulated 5V power supply with each Base Station and
2. A Worth Data regulated 5V power supply with each Base Station and
Laser Scanner ordered. TO PREVENT DAMAGING the Base Station
or RF Laser, DON'T USE ANY OTHER BRAND OF POWER
SUPPLIES.
or RF Laser, DON'T USE ANY OTHER BRAND OF POWER
SUPPLIES.
3. Either a serial cable (F36) or USB cable (C21), depending on which one
you ordered.
4. A
laminated
RF Laser Reader Setup Menu sheet.
5. A plastic barpad for entering variable quantity information and
performing the Link Test without data transmission.
Scanner Beeps and LEDs (what they mean)
When you scan, you will get one beep when you get a successful decode and a
high-pitched beep. The data is then transmitted to the Base Station (as it is
being transmitted, the LED flashes yellow). When the Laser receives the
acknowledgement from the Base Station that the data has been received, the
Laser emits a lower pitched beep and turns on a green LED for three seconds.
If the transmitted data fails to be acknowledged,
1) further scanning is prohibited. You can't pull the trigger again
until the data reaches the base or until you clear the scanner.
2) The laser will retransmit three times, (the yellow LED will
indicate retransmissions).
3) If it fails three times, it will emit a distinct 8 beep pattern and
turn off. This is your clue to check out the Base Station.
4) You can pull the trigger to try transmission again. (the laser beam
will not come on until the transmission is acknowledged or you
hold the trigger down for 30 seconds to clear the data).
hold the trigger down for 30 seconds to clear the data).