1027144– 0001   Revision D
 5–4  Installing mast mounts
RT installation
The standard nonpenetrating roof mount, HNS 9200375–0001, is a
flat, metal–frame mount assembled from a kit. It requires a
6.5–by–6.5–foot space (1.98 by 1.98 meters) and includes a 7–foot
(2.1–meter) mast. You install the mount on a rubber pad; concrete
blocks are added for ballast.
The standard mount can be used on a variety of flat roof types, as
detailed below.
Instructions are given below for various types of roofs. See also
the manufacturer’s instructions, which are included in the mount
shipping carton.
Most flat roofs are topped with:
Glued rubber cap sheet or
Rubber cap sheet with gravel
Follow these instructions for either type of roof:
1.
If the cap sheet is covered with gravel, use a push broom or
snow shovel to clear the gravel from the area where the
mount will be installed, as shown in figure 5-2.
Figure  5-2
Clearing gravel from the installation location
T0006061
2.
Place the rubber pad on the roof surface where the mount
will be assembled.
5.5
Standard
nonpenetrating
mount
Flat roof – rubber sheet
(with or without gravel)