JVC KENWOOD Corporation 408000 ユーザーズマニュアル

ページ / 88
63
•  Press 
[CALL] to delete the character at the current cursor  
position.
6   To complete the entry, press [MENU] without selecting a 
character. Otherwise press 
[PTT] to cancel the entry.
p
rograMMaBle
 vFo
If you want to limit the operating frequencies within a certain range, 
program the upper and lower frequency limits to the programmable 
VFO parameters.  For example, if you select 144 MHz for the lower 
limit and 145 MHz for the upper limit, the tunable range will be 
limited from 144.000 MHz to 145.995 MHz.
1   Press [VFO].
2   Enter Menu mode and access Menu No. 1 (P.VFO).
3  Press [MENU].
•  The current programmable frequency range for the band 
appears.
4   Rotate the Selector (or press [UP]/ [DOWN]) to select the lower 
limit frequency in MHz.
5   Press [MENU] to store the lower limit frequency.
•  The upper limit frequency blinks.
6   Rotate the Selector (or press [UP]/ [DOWN] to select the upper 
limit frequency in MHz.
7   Press [MENU] to store the upper limit frequency.