Yaesu Musen Co. Ltd. 30443X3D ユーザーズマニュアル
Page 51
GX2200
4. When a DSC distress acknowledgment is
received, a distress alarm sounds and Channel
16 is automatically selected. The display shows
the MMSI of the ship responding to your distress.
RECEIVED ACK: acknowledgment signal is
received.
RECEIVED RLY: relay signal is received from
a n o t h e r v e s s e l o r c o a s t
station.
!DISTRESS ALERT!
Nature of:Undesignated
Position:
POS Time: 10:00
Wait for ACK
TX in: 02:25
N
W
33 37.120
118 09.580
PAUSE
CANCEL
!DISTRESS ALERT!
Received Acknowledged
Name:USCG
Since: 00:15
ID:101234
567
OK
5. Press the
PTT switch and state your name, vessel name, number of
persons on board and the distress situation, then say “over” and wait for
a reply from the acknowledging ship.
6. To turn off the distress alarm before the radio retransmits the distress
call, press the
9
16
key.
Transmitting a DSC Distress Alert with Nature of Distress
The
GX2200 is capable of transmitting a DSC distress alert with the following
“Nature of Distress” categories:
Undesignated, Fire, Flooding, Collision, Grounding, Capsizing, Sinking,
Adrift, Abandoning, Piracy, MOB
1. Press the
CALL
MENU
key. The “D S C M e n u ” will
appear.
)TQWR
+PFKXKFWCN
#NN 5JKRU
215 4GRQTV
2154GSWGUV
&5% /GPW
&+564'55#.'46/5)
37+6
5'.'%6
&+564'55#.'46/5)
0CVWTG QH7PFGUKIPCVGF
2QUKVKQP
215 6KOG
0
9
9
37+6
0#674'
2156/
2TGUU=&+564'55?UGE
HQT&+564'55VTCPUOKV
!NATURE OF!
Fire
Flooding
Flooding
Grounding
Capsizing
Capsizing
Collision
UNDESIGNATED
QUIT
SELECT
!NATURE OF!
Undesignated
Flooding
Grounding
Capsizing
Capsizing
Collision
FIRE
QUIT
SELECT
2. Rotate the
CH knob to select “DISTRESS ALERT
MSG”.
3. Press the
soft key. (To cancel, press the
soft key.) The “DISTRESS ALERT MSG”
menu will appear on the display.
4. Press the
soft key, then rotate the
CH
knob to select the desired nature of distress cate-
gory.
Nature of distress categories: Fire, Flood, Colli-
sion, Grounding, Capsizing, Sinking, Adrift, Aban-
doning, Piracy, and MOB.
5. Press the
soft key.
6. Press and hold the
DISTRESS
key until a distress
alert is transmitted.
7. Perform the steps 1 through 6 of the basic opera-
tion described in the previous section.
FCC ID:K6630443X3D
IC:511B-30443X3D
YAESU MUSEN CO., LTD.