EMS Technologies Canada Ltd. HSD-X ユーザーズマニュアル

ページ / 366
Page 1–18
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
Transceiver output impedance
50 ohms
VSWR
2:1 maximum
Input level operational
 
Input level no damage
-107 dBm to -47 dBm
+10 dBm
External (Digital) Interfaces
Crosstalk Bus
ARINC 429 high-speed (100 kbps) data bus
Maintenance Port RS-232 Data 
loader 
 
Front and Rear Connector
RS-232 serial bus supporting 57.6 kbps data 
load capacity
ISDN User Interface
64 kbps ISDN Euro input and output
 Table 1–16. HSD-X RTCA/DO-160D Environmental Specifications
CHARACTERISTIC
SPECIFICATION
Temperature and Altitude
Categories: A4 (without cooling air)/ C4 (with 
cooling air)
Low operating temperature 
-40 °C (A4), -40 °C (C4) 
High operating temperature
+55 °C (A4), +70 °C (C4)
Altitude
Maximum operating altitude: 15,000 ft 
(A4)/55,000 ft (C4)
Loss of cooling
Category Y
Temperature Variation
Category B
Humidity
Category A
Shock
Category B
Vibration
Category SB
Explosion Proofness
Category E
Waterproofness
Category X
Fluids Susceptibility
Category X
Sand and Dust
Category X
Fungus Resistance
Category F
Salt Spray
Category X
Magnetic Effect
Category Z
Power Input
Category A
Voltage Spike
Category A
Audio Frequency 
Category A
Induced Signal
Category C
RF Susceptibility
Category RR
 Table 1–15. HSD-X Transceiver Specifications
CHARACTERISTIC
SPECIFICATION