2.1 
Pico Base Installation Location 
WARNING! 
T
HE 
P
ICO 
B
ASE UNIT MUST ALWAYS BE INSTALLED VERTICALLY AND TOP
-
DOWN 
 
 
WITH THE CONNECTORS ON THE UNDERSIDE FOR PROTECTION
This section describes the criteria that should be considered when selecting the Pico Base 
installation location. 
2.1.1 
Criteria for Outdoor Locations 
Take into account your site plan and local regulations that define distance from populated areas. 
 
The unit should be mounted in the highest possible point. Reception will increase according 
to the height of the antennas. 
 
There should be minimum obstacles between the antenna and the planned coverage area 
(zone) – minimum of 55% exposure to the sky. 
 
Take into account (according to your coverage site plan) distance from other antennas or 
devices that may cause interferences. 
 
Accessibility for maintenance (where possible). 
2.1.2 
Criteria for Indoor Locations 
 
A minimum of 55% direct LOS exposure of the external GPS antenna to sky. 
 
Maximum distance between external GPS antenna to Pico Base = 22 meters.  
 
2.1.3 
Antenna Grounding Requirements 
The antenna installation must be as per Article 810 of the NEC. Of particular note is the 
requirement that the grounding conductor not be less than 10 AWG (Cu). The scheme should 
either correspond to UL 96 and 96A. Lightning Protection Components and Installation 
Requirements for Lightning Protection Systems, or tested in according to UL 50 and UL 497.