CALAMP WIRELESS NETWORKS INC. BDD4T881 ユーザーズマニュアル

ページ / 66
120 20170-200
Paragon
PD
 Technical Manual
10
  Monitor Mute switch - opens the mute, al-
lowing continuous monitoring of the audio
signal.
On = audio muted
3.1.1.2 Exciter 
module
The Exciter’s front panel controls and indicators
are:
Figure 7 - Exciter module, front panel
  Carrier Switch - momentarily keys the
transmitter ON while pressed (used for test
purposes only).
  On LED - is lit when transmitting
  Line Sensitivity – not used.
  Supply LED - is lit when DC power is ap-
plied. Fast Flashes when linked with
PGM800Win. Slow Flashes indicates VCO
(synthesizer) out of lock. Unequal Flashes
indicates internal communication error.
  Microphone Socket – not used.
3.1.1.3 
Power Amp module
The Power Amp front panel and indicators are:
Figure 8 - Power Amp module, front panel
  Supply LED - is lit when DC power is ap-
plied.
  Low Forward Power LED - is lit when for-
ward power is below the level set, normally
80% of nominal forward power.
  High Reverse Power LED - is lit when high
reverse power is detected (e.g. VSWR= 3:1).
  Power - sets the PA output power:
VHF & UHF: 20 – 100 Watts
800: 20-70 Watts
3.1.1.4 Speaker 
panel
Referring to Figure 9, the speaker panel is fitted
with a 4
Ω
 speaker.
Both series of radio assemblies share the same
front panel fitted with an RJ11 connector. This
connector is used to allow programming the ra-
dio from the front of the unit via a programming
lead. This feature is exclusive to the Series II
modules.
Carrier
Switch
On
LED
Supply
LED
Line
Sensitivity
Microphone
Socket
®
Exc iter
Carrier
O n
Line
Sensitivit y
Supply
Microphone
®
Power Amplifier
Low Forward Power
Supply
High Rev ers e Power
Power
Supply
LED
Low Forward
Power LED
High Reverse
Power LED
Power
Adjustment