Table 10 - Checklist B (General)
CHECKLIST B (Paragon
PD+
)
General Check out (part1 of 2)
Paragon
PD+
 units are set and characterized at the factory to optimize performances.
It is not recommended to try readjusting units unless it is really required.
Misadjusting a unit may result in significant performance losses.
The proposed adjustments in the "IF NOT?" column below, should be tried ONLY if system data
performance degradation is noticed combined with out-of-tolerance items.
Step
ACTION
Expected Results at 25
°°
C
MEASURE WITH
IF NOT?
1
Normal Power-up
Sequence
BDLC
PD+
 beeps once, all LEDs come ON for about four seconds, the green LEDs
then flash in a “ripple” pattern for close to two seconds. All LEDs go OFF except the
CK that should flash 6 to 8 times per second. For functions, see section 3.2.1.5
2
Connect and save
unit config
Press WinRIS Get
button
as per WinRIS Help content
3
Transmitter Output
Power
Press TX ON (Unmod)
VHF/UHF: 20 - 100 watts
800 MHz: 20 - 70 watts
900 MHz: 65 - 100 watts
+10%, -10%
Service monitor set
to read power
or
150W in-line watt-
meter installed as
close as possible
to the unit antenna
connector.
Adjust “Power” on the front
panel of the “Power Amp”
( see                                                                                                                    
Figure 
8
)
4
Transmitter
Reflected Power
Press TXON (Unmod)
< 5% of forward power or
as specified by System
Engineering.
10 W in-line
wattmeter
Check for bad connections,
damaged coax cable, etc.
5
Carrier Frequency
Error
Press TX (Unmod)
< ±300 Hz
Service monitor set
to read frequency
error
Adjust TCXO (IC700)
(see inside Exciter module at,
Figure 28 (800), Figure 30
(UHF), Figure 32 (VHF) )
6
TX Deviation (KHz)
Press
 TX (Unmod  
Carrier will be modu-
lated with a 1 kHz tone.
Refer to "
Figure 16 - Carrier
deviations for Tone or Data
Modulation
 per bit rates
Tolerance is +5%, -10%
for all bit rates.
Service monitor set
to read deviation.
(IF filter set to Mid
or 30 kHz position)
Adjust according to 
Appendix 1
- ParagonPD+ Deviation adjust
on page 48
7
Low Frequency
Balance
Initiate a
TX Random data
test
via BDLC
PD+
’s PF1
(See Table 4)
a) Record deviation level
read from step 6
b) Record deviation read
from TX Random test
c) Difference between
a) and b) should be:
< 600 Hz (DGMSK)
< 1.5 kHz (xRC4FSK,
                 xRC8FSK, HC)
< 2.0 kHz (xRC4FSK,
                 xRC8FSK,
                 FC/NPSPAC)
Service monitor set
to read deviation
 (IF filter set to Mid
or 30 kHz position,
all audio filtering
disabled )
Refer to
Section 5.2.3.4