CALAMP WIRELESS NETWORKS INC. GPD9 ユーザーズマニュアル

ページ / 23
122 20130-005
G3 Installation Guide
17
Table 1 - G3 LEDs indications
G3 LEDs indications
Power-on Sequence (LEDs are paired)
Normal Operation (LEDs are independent)
PWR
RX / TX
Indication
PWR
Indication
RX / TX
Indication
Red
Red
Normal boot-up
start
(10 to 27 sec.)
Green*
Normal ready state
Off
No network activity
Amber
Off
Then 8 seconds
to completing
boot-up
N
o
rm
a
l
Green
Off
Normal state
Amber*
1 Pulse per sec (1 pps)
Sufficient satellites
acquired by GPS
Green
Receiving packets
“DBA sync” allows transmit
Red
Off
Hardware failure
flashing
Red
-
Missing DSP
RSSI calibration
Amber
Receiving packets
“DBA out-of-sync” prevents
transmit
E
rr
o
rs
Slow
Red/Green
Red
Software failure
(firmware erased)
Red
Transmitting
S
p
ec
ia
l
Fast
Red/Green
Red
Programming in
progress
* For 800 & 900 MHz US models (using Transmit duty cycle limit firmware) :
- PWR lit Green = normal indication or Flashing Amber = normal + 1pps
- PWR lit Amber = exceeded duty-cycle or Flashing Green = exceeded d-c + 1pps
3.2 DTE Port Interface
For all three ports, we recommend the use of a shielded 9-wire cable with all pins connected. These ports
can be used for unit configuration, maintenance, & adjustment as well to connect user applications.
Table 2 - DTE port pin functions
DE-9 F pin #
Function
1
DCD – from G3, normally asserted
2
RXD – data from G3
3
TXD – data to  G3
4
DTR – to  G3, handshaking
5
Ground
6
DSR – from  G3, tied to VCC through current limiting resistor
7
RTS - to  G3, handshaking
8
CTS – from  G3, handshaking
9
AUX - auxiliary input to G3,  (for port 2:
 “Officer requires assistance”
 Alarm input)
It may be activated by (normally open) dry contact pull-up to the port’s DSR output. It may also tolerate
user pull-up to external +12 VDC (car battery), but an isolated dry contact is preferred due to the risk of
noise-related false alarms caused by the vehicle’s electrical system.
A +3 to +12 V signal at this pin will send a DMP “x” (On) message to the base.
An open or ground signal will send a DMP “y” (Off) message.
Messages are only sent when a signal transition occurs.
See Appendix “A” on page 24 for further details.
3.2.1 RS-232 Interface Signal Levels
In the descriptions of data signals, the following conventions are used:
Table 3 - RS-232 Signal Levels
Term
Alternates
Signal level
ON
asserted, spacing
+3 to +15 V
OFF
dropped, marking
-3 to -15 V