Receiver Programming
S
E
C
T
I
O
N
3
Enroll & Program Devices
This section describes how to enroll and program:
• wireless devices using zones (WLS904P, WLS906, WLS907, WLS912, WLS914 and
WLS925L)
• wireless keys (WLS909, WLS919)
For more information on these devices, read the instruction sheet included with each
device.
device.
3.1 A Note about Electronic Serial Numbers
An electronic serial number (ESN) is printed on the back of each wireless device. ESNs
are used to enroll the wireless devices with the RF5501-433 keypad.
are used to enroll the wireless devices with the RF5501-433 keypad.
In order to reduce the occurrence of wireless devices with the same serial number, 6-
digit serial numbers are now printed on the back of each wireless device.
digit serial numbers are now printed on the back of each wireless device.
NOTE: 6-digit serial numbers are only supported on the following control panels: PC5010
v2.x and higher, PC5015 v2.2, PC5020, PC5008, PC1555 and PC580.
v2.x and higher, PC5015 v2.2, PC5020, PC5008, PC1555 and PC580.
The 6-digit serial numbers include hexadecimal digits. For instructions on programming,
hexadecimal numbers, see your system
hexadecimal numbers, see your system
Installation Manual, section 4: How to Program.
When connecting the RF5501-433 to a PC5010, PC5020 or PC5015 v1.x panel, enter 5-
digit serial numbers only.
digit serial numbers only.
When connecting the RF5501-433 to a PC5010 v2.x, PC5015 v2.x, PC5020, PC5008,
PC1555 or PC580 panel follow the instructions below.
PC1555 or PC580 panel follow the instructions below.
Old Wireless Device ESNs
You can use older devices on all versions of the RF5501-433 keypad, even though they
only have a 5-digit ESN. When using older wireless devices:
only have a 5-digit ESN. When using older wireless devices:
Enter [0] + 5-digit ESN
3.2 Enroll Wireless Devices Using Zones
Enroll wireless devices which use zones (universal transmitters, motion detectors,
smoke detectors, and panic pendants):
smoke detectors, and panic pendants):
1. At a system keypad, enter [
✱][8][Installer’s code] to go the installer’s programming
section.
2. Enter programming section [804].
3. Enter the 2-digit number corresponding to the zone the device is to occupy ([01] to [32]).
NOTE: Hardwired and wireless devices cannot be assigned to the same zone. PC5108
zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-12 and zones 13-
16). None of the zones assigned to a PC5108 module may be used for wireless de-
vices. For more information on zone assignment, consult your system Installation
Manual.
zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-12 and zones 13-
16). None of the zones assigned to a PC5108 module may be used for wireless de-
vices. For more information on zone assignment, consult your system Installation
Manual.
4. Enter the device’s ESN. The entry
must be six digits. If an older device with a 5-digit
ESN is being enrolled, add the digit [0] to the beginning of the ESN. (E.g.,
ESN=21234, enter 021234)