Digital Security Controls Ltd. 03RF5108 ユーザーズマニュアル

ページ / 24
4
S E T U P & W I R I N G
2.6 RF5108-433 Programmable Outputs - PGM1 and PGM2
Each PGM output is an open collector switch to ground.
That is, when the PGM output is activated the terminal
will switch to ground.  PGM1 and PGM2 are able to sink
up to 300mA of current.  If more than 300mA of current
is required a relay must be used. Refer to diagram
shown at right.
2.7 Connecting LED to the RF5108-433
The LED can be used
to indicate whether the
system is armed or dis-
armed. If the output is
programmed as an armed status output, the red LED will
turn on when the system is armed and will turn off when
the system is disarmed.
2.8 Connecting a Garage Door to the RF5108-433
Connect an output of the RF5108-433 across the wall-mounted
push button or directly at the motor of the garage door opener
(please consult the garage door opener instructions for proper
connections).  Set up the system and wireless key so that it is
programmed to pulse an output for a short duration (5 seconds)
so that every time the programmed key is pressed the garage
door is opened or closed. The system can also be set up so that
an output on the RF5108-433 will follow a main panel output that
is programmed as a command output and is set up on the
wireless key as such. Doing this will also activate an output on
the RF5108-433 for 5 seconds (please refer to the control panel
manual for a listing of available output types and their func-
tions). PGM 1 and/or PGM 2 on the RF5108-433 can be set up
to open a garage door (refer to Section 3.5).
2.9 Connecting an X-10 Powerflash Module to the RF5108-433
When connecting an X-10 Powerflash module to the RF5108-
433, different lights within or outside the home can be control-
led, such as table lamps, or porch and driveway lights that
illuminate the entry / exit paths.  This can be done by setting up
the system and wireless key in one of several ways:
• The wireless key can toggle an output ON/OFF, triggering the
X-10 Powerflash module, providing direct control of lighting.
• The wireless key can turn on an output for a programmable
amount of time (5 seconds to 99 minutes and 99 seconds),
turning on lights for the amount of time the homeowner requires.
PGM1
GRN
YEL
BLK
RED
PGM2
DSC
RM-1C
RED
BLK
WHT (COM)
YEL (NC)
GRN (NO)
PGM1
GRN
YEL
BLK
RED
PGM2
RED
BLACK
PGM1
GRN
YEL
BLK
RED
PGM2
DSC
RM-1C
RED
BLK
WHT (COM)
YEL (NC)
GRN (NO)
Garage door
pushbutton
or motor
PGM1
GRN
YEL
BLK
RED
PGM2
DSC
RM-1C
RED
BLK
WHT (COM)
YEL (NC)
GRN (NO)
X-10
Powerflash
Module
Lamp
Module