Everspring Industry Co Ltd HSP02 ユーザーズマニュアル
2
Inclusion
1. Have Z-Wave Controller entered inclusion
mode.
2. Pressing link key 3 times within 1.5
seconds will enter inclusion mode.
3. The unit will stay “awake” for 10 minutes.
Exclusion
1. Have Z-Wave Controller entered exclusion
mode.
2. Pressing link key 3 times within 1.5
seconds will enter exclusion mode.
3. The unit will stay “awake” for 10 minutes.
2-second on, 2-second
off (for 2 minutes)
Reset
1. Press link key 3 times within 1.5 seconds.
2. Within 1 second, press and hold link key
for 5 seconds until LED is OFF.
3. IDs are cleared and all settings will be
reset to factory default.
2-second on, 2-second
off (for 2 minutes)
Association
1. Have Z-Wave Controller entered
association mode.
2. Pressing link key 3 times within 1.5
seconds will enter association operation.
The unit will stay “awake” for 10 minutes.
The unit will stay “awake” for 10 minutes.
3. There are two groupings – 1 and 2. Refer
to Z-Wave’s Grouping as described on
page 4.
page 4.
Ú
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Ú
Failed or successful results in including/excluding the node ID can be viewed from the
Z-Wave Controller.
Ú
When “Exclusion” is compl eted, the p arameter 1 of configur ation will be restored t o
default value, while other parameters will retain their settings before exclusion. Press
the tamper switch (link key) once and the green LED will flash for about 25 seconds.
the tamper switch (link key) once and the green LED will flash for about 25 seconds.
Choosing a Mounting Location
The PIR Detector is suitable for mounting in dry interior locations only.
The recommended position for a PIR Detector is in the corner of a room mounted at
a height between 1.8 and 2m. At this height, the detecto r will have a maximum
range of up to 9m with a field of view o f 110°, subject to the position for the P CB
being set in 5. (FIGURE 1& 2) The position of the PCB inside the PIR can be set to
5 different positions to adjust the range of the detector. Setting the PCB in position 3
will reduce the range to 6m approximately, with position 1 providing a range of 3m
approximately. The recommended position setting for the PCB is in position 5.
PCB Position
Range
1
3m
3
6m
5
9m
FIGURE 1& 2
When considering and deciding upon the mounting position for the detecto r the
following points should be considered to ensure trouble free operation:
1. Do not locate the detector facing a window or where it is exposed to or facing
direct sunlight. PIR Detectors are not suitable for use in conservatories.
2. Do not locate the detector where it is exposed to ventilators.
3. Do not locate the detector directly above a heat source, (e.g. fire, radiator, boiler,
etc).
4. Where possible, mount the detector in the corner of the room so that the logical
path of an intruder would cut across the fan detection pattern. PIR detectors
respond more effectively to movement across the device than to movement
directly towards it. (FIGURE 3)
Less Sensitive More Sensitive
FIGURE 3
1
2
3
4
5
6
7
8
9
10
11
12
0
13
2M