Bureau D' Electronique Appliquee Inc MATRIX ユーザーズマニュアル

ページ / 6
75.1046 V3 July 2005 [Rev. 7/21/2005]
 
 
Page 1 of 6 
The MATRIX Digital Inductive Loop Detector is the ideal solution for parking barrier control, motorized gates and doors, vehicle 
access control and industrial control systems.  
The MATRIX is a high performance single or dual-channel vehicle detector packaged in a compact housing.  The connection is 
made with a standard industrial 11-pin round connector.   
The six versions listed below include single or dual-channel, and 3 possible power supplies: 
10MATRIXS110
 
Single loop detector with 110 to 120 V AC power supply. 
10MATRIXS220
 
Single loop detector with 220 to 240 V AC power supply. 
10MATRIXS1224
 
:  
Single loop detector with 12 to 24 V AC/DC power supply. 
10MATRIXD110
 
Dual loop detector with 110 to 120 V AC power supply. 
10MATRIXD220
 
Dual loop detector with 220 to 240 V AC power supply. 
10MATRIXD1224
 
:  
Dual loop detector with 12 to 24 V AC/DC power supply. 
 
 
Technology
 
:  Inductive loop 
Tuning 
:  automatic  
Detection mode
  :  presence
 
Presence time  
:  1 min to infinity (permanent  
 
  presence) with 250 steps.  
Pulse time output
 :  100 ms or 500 ms
 
Inductance range 
 :  20 µH to 1000 µH 
Frequency range 
:  20 kHz to 130 kHz 
Frequency steps  
:  4 for single loop  
 
  2 for dual loop (for each loop) 
Sensitivity (L/L) 
:  0.005% to 0.5% with 250 steps 
Reaction time  
:  25ms for single loop  
 
  50ms for dual loop(each channel)  
Setup time at power on 
:  8 s max by channel  
Setup time after configuration 
:  2s max by channel  
Power supply (depending on model) 
:
 
 
• 
12-24 AC/DC 
±
 10% 
• 
230VAC 
±
 10 % 
• 
115VAC 
±
 10 % 
Power Frequency
 
   : 48 to 62 Hz 
Power Consumption   
: < 2.5 W  
 
Temperature range
     : -22
°
F to 158
°
F  
 
 
 
 
[-30°C to +70°C]
 
Degree of protection  
: IP40 
2 Output relays (free potential change-over contact) 
:
 
 
 Max contact voltage : 230 VAC ; 
 
 Max contact current : 5A (resistive). 
 
LED indicators
 
:   
 
 1 green LED : power ;  
    
 
 1 red LED : Loop status 1 ;  
 
 1 red LED : Loop status 2. 
Protections 
  :
 
 
 
• 
loop insulation transformer ;
 
 
• 
Zener diodes ; 
 
• 
gas discharge clamping. 
Connection 
:
 
 
Standard 11-pin round connector 86CP11 
Dimensions  
: 3 in (H) x 1.5 in (W) x 3 in (D) 
 
  [
77mm (H) x 40mm(W) x 75mm(D)]
 
Weight
  
:  7 ounces [< 200g] 
Product compliance
   :  
 
R&TTE 1999/5/EC 
 
EMC 89/336/EEC 
 
FCC 47CFR15 
 
IC RSS-210 Issue 5 
 
  
 
 
 
• 
Shut off all power before attempting any wiring procedures. 
• 
Maintain a clean & safe environment. 
• 
Constantly be aware of traffic around the door or gate area. 
• 
Always suspend traffic through the doorway or gate area when performing testing that may result in unexpected 
reactions by the door or gate. 
• 
Always check placement of all wiring and components before powering up to insure that moving parts will not catch 
any wires and cause damage to equipment. 
 
 
DESCRIPTION 
OF THE 
SENSOR   
 
APPLICATIONS 
 
TECHNICAL  
SPECIFICATIONS
 
1.5 in 
3 in  
3 in  
SAFETY 
PRECAUTIONS 
 
We open up New Horizons
USERS GUIDE
  
MATRIX 
DIGITAL INDUCTIVE LOOP SENSORS