Psion Inc 7505BTHC25 ユーザーズマニュアル

ページ / 166
142
iKôn Rugged PDA (Windows Mobile 6) User Manual
Chapter 5: Settings
Decoded (Internal) Scanners
Code 93
2D UPC Half Block Stitching
Setting this parameter to on enables “UPC Half Block Stitching” for the SE 3223 omnidirec-
tional engine only.
5.28.1.14Code 93
Enabled
Set this parameter to on to enable “Code 93” or off to disable it.
Set Length L1 And Set Length L2
Lengths for “Code 93” can be set for Any lengthLength within a rangeOne discrete length 
or Two discrete lengths. The length of a code refers to the number of characters (i.e., human 
readable characters), including check digit(s).
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where 
you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a selected 
length. Choosing Two discrete lengths allows you to decode only those codes containing two 
selected lengths. Length within a range allows you to decode a code type within a specified 
range from 4 to 55.
Field Size/Char
Refer to page 137 for details.
5.28.1.15Codabar
Enabled
Set this parameter to on to enable “Codabar” or off to disable it.
Set Length L1 And Set Length L2
Lengths for “Codabar” can be set for Any length, Length within a range, One discrete length 
or Two discrete lengths. The length of a code refers to the number of characters (i.e., human 
readable characters), including check digit(s). 
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where 
you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a selected 
length. Choosing Two discrete lengths allows you to decode only those codes containing 
two selected lengths. Length within a range allows you to decode a code type within a spec-
ified range from 5 to 55.