Chapter 5: Settings
Decoded
iKôn Rugged PDA (Windows Mobile 6) User Manual
157
Plessy Transmit Check Digit
If the check digit is to be transmitted with the Plessy data, this parameter must 
be enabled.
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to 
the number of characters (i.e., human readable characters), including 
check digit(s). 
Plessy Minimum Length
Minimum lengths for the Plessy bar code can be set from 0 to 255. The length of a code 
refers to the number of characters (i.e., human readable characters), including 
check digit(s). 
Field Size/Char
Refer to page 137 for details.
5.28.2.13Code 11
Enabled
Set this parameter to on to enable “Code 11”.
Check Digit Verification
The available options for this parameter are MOD 10 Check and Double MOD 10 
Check
.This parameter uses the specified algorithm of the option you've chosen to ensure the 
integrity of the symbol data before transmitting. If the data does not contain that algorithm, 
the data is not transmitted. 
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to 
the number of characters (i.e., human readable characters), including 
check digit(s). 
Field Size/Char