Chapter 5: Settings
Options Tab
172
iKôn Rugged PDA (Windows Mobile 6) User Manual
5.28.4 Options Tab
This tab allows you to tailor the double-click parameters and the display options associated 
with your scanner.
5.28.4.1 Double Click Parameters
Click 
Time (msec)
This parameter controls the maximum gap time (in milliseconds) for a double-click. If the 
time between the first and second clicks of the scanner trigger is within this time, it is con-
sidered a double-click. The allowable range is 0 to 1000. A value of zero disables this 
feature.
A double-click produces different results depending on whether or not a value is assigned in 
the “Click Data” parameter. When a value is not assigned for the “Click Data”, double-click-
ing the scanner trigger overrides the target dot delay set in the “Dot Time” parameter and 
initiates a normal scan sweep. If a value is assigned for the “Click Data” parameter, double-
clicking the scanner trigger inserts the “Click Data” value rather than initiating a scan.
Click Data
For both integrated and external scanners, this parameter determines which character is sent 
to the application installed in your PDA following a double-click. A dialog box appears, 
asking that you press the key you want to insert. The ASCII/Unicode key value of the key-
press is displayed.