ETC03N01
 
 
 
 
 
 
The  ETC  tag  has  Tamper  and  Button  Press  inputs;  designated  
B1 and B2: 
 
 
B1 – Monitors press/ release button activity 
 
B2 – Monitors tamper functionality 
 
 
The ETC tag reports the state of the tamper sensor on B2. When 
Tamper  is  detected  (detached),  B2=1.  When  attached,  B2=0.  An 
EVENT  message  is  transmitted  when  there  is  a  change  from 
attached to detached or vice versa. When there is a change from 
attached to detached (i.e. tampering), then there is a transmission 
of EVENT of 4 messages, 400 ms apart and B2=1. When attached, 
there  is  a  transmission  of  EVENT  of  4  messages,  400  ms  apart 
and B2=0. 
 
In  the  steady  state,  the  B2  bit  provides  the  status  of  the  tamper 
sensor  (if  the  equipment  tag  stays  attached,  B2=0,  if  stays 
detached, B2=1). 
 
   !
"" #
$ "
 
After  button  press,  4  messages  are  transmitted  (each  message 
about 2ms in duration), 400 ms apart, with B1=1. When the button 
is released, B1=0.  
An  additional  4  messages  (each  message  about  2ms in duration) 
are transmitted 400 ms apart. In the steady state (no button press / 
button release) B1=0. 
% ! 
!" &""& ! &!
' !
Tag in Motion: 
 
LF Response Time: In this state, the onboard LF receiver activates 
every 0.6 sec to check if the tag is in a LF zone. 
 
Transmission Rate: Burst of 4 RF transmissions(each transmission 
about 2ms in duration), approxamately 0.4 secs apart. 
 
Message Type Transmitted: IR/RF Data Message with Data byte 
indicating ID# of received Low Frequency LF RDR and motion bit 
M=1. 
 
Tag Motionless
 
LF Response Time: In this state, LF receiver activates every 15 
seconds to check if the tag is in a LF zone. 
 
Transmission Rate: Burst of 4 RF transmissions(each transmission 
about 2ms in duration), approxamately 0.4 secs apart. 
 
Transmitted Message Type: IR/RF Data Message with Data byte 
indicating ID# of received Low Frequency LF RDR and motion bit 
M=0 
 
 
 
 
 
(
 
1.  Suspend usage of the ETC tag using the Eiris software. 
 
2.  Remove the tag from the mounting bracket using a small 
flat-head screwdriver to release the clip that holds the tag 
in place (Para 3, Figure 5). 
 
3.  Unscrew the 4 screws situated at the back of the tag and 
remove the back cover from the (Figures 1 and 2). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
4.  Carefully slide the battery out from under the battery 
holder to reveal the battery isolator (Figure 3). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5.  Before inserting a new battery into place, position the 
battery Isolator such that the holes are aligned with the 
contact pins (Figure 3). 
 
6.  Replace the battery ensuring that the positive (+) side of 
the battery faces the PCB. 
 
7.  Close the back cover such that the screw holes are 
aligned an tighten the 4 screws into place (Figure 4). 
 
 
 
 
 
 
 
 
 
ETC tags require activation before use. 
To activate : Press and hold the button for  
5 seconds. 
Upon activation the LED blinks, indicating 
transmission.
 
Back cover screw 
Battery holder 
Battery 
Battery isolator 
Contact pin 
Back cover 
Figure 1: ETC Tag (showing screws) 
Figure 2: ETC Tag (back cover removed) 
Figure 3: ETC (battery removed) 
Figure 4. ETC Tag