Visonic Inc. MKP150 ユーザーズマニュアル

ページ / 7
DE2462U 
 
MKP-150 
2-Way Wireless Keypad 
User's Guide
1. INTRODUCTION
NOTE: RELEVANT TO POWERMAX+ VERSION B AND ABOVE 
The device operates using two-way encrypted coded 
transmission and provides aural and visual indications. For each 
PowerMax+ control panel, a maximum of two MKP-150 keypad 
devices may be enrolled. 
The MKP-150 may be operated either by AC power supply or by 
battery power. If AC power is used, the device operates 
continuously and the system status is c onstantly updated. If 
powered by batteries, the keypad enters sleep mode 15 sec after 
last key press. The keypad immediately becomes operational 
again upon pressing of any key. 
Note: In the event of an AC power failure, the MKP-150 operates 
on batteries as described above. 
The device enables the user to arm/disarm the alarm system, to 
initiate emergency/fire/panic alarms (panic alarm is not operative 
in UK) and to turn lighting devices on and off. 
The main features of the MKP-150 are: 
• Status,
 
alarm 
 
memory,
 
and
 
trouble
 
data
 
retrieval
 
from
 
PowerMax+. 
•  Automatic reporting to PowerMax+ of low battery voltage, AC 
failure, tamper. 
•  Visual indications by red/green/amber LED and LCD display. 
•  Keypad and LCD back lighting activated by long press (2 sec) 
of any key. 
•  Light dim / brightness 
•  Various audible signals sounded by the speaker in response to 
specific actions. 
•  Automatic supervision messages. 
•  Diagnostic test of PowerMax+. 
•  Two long-life 3 Volt Lithium batteries. 
• Wall mounting. 
• Friendly programming. 
The Power (green) LED lights when operated using AC power. The 
Trouble (amber) LED lights if a "trouble" state is currently detected 
within the PowerMax+. The Chime (green) LED lights when the 
chime function is active. The Arm (red) LED lights when the 
system is in armed state (away mode), or flashes (home mode). 
A periodic supervision message is transmitted, at regular intervals, 
from the MKP-150 to the PowerMax+ control panel. This ensures 
MKP-150 active participation in the system. 
Operating power is obtained from two 3 Volt Lithium batteries, or 
by AC. A weak battery causes a "low battery" message to be sent 
to the PowerMax+. 
A Screen Saver appears on the display (if enabled by the installer 
on the PowerMax+ unit) when no key is pressed for more than 30 
seconds. The display reads “POWERMAX” and the LEDs do not 
light (to prevent an intruder of knowing the system status). The 
normal display returns after pressing the OFF button followed by 
entering user code (Refresh by Code) or after pressing any key 
(Refresh by Key), depending on the PowerMax+ settings of the 
installer. If Refresh by Key was selected, the first key press (except 
for Fire and Emergency) causes the normal display to return while a 
second press performs the key function. In the case of the Fire and 
Emergency keys, the first key press causes the normal display to 
return and also performs the Fire/Emergency function. 
 
AWAY
MICROPHONE
PLAY MESSAGE
VOLUME UP /
LIGHT BRIGHT
VOLUME DOWN /
LIGHT DIM
CHIME ON/OFF
MUTE SPEAKER
NO ENTRY DELAY
RECORD MESSAGE
LIGHT OFF
TESTING
ARMING
“AWAY”
ARMING “HOME”
DISARMING
BYPASS
LIGHT ON
EMERGENCY
(Hold for 2 sec.)
(Hold for 2 sec.)
FIRE
PANIC
(press both buttons)
“SHOW / OK”
BUTTON
“ESCAPE”
 BUTTON
“NEXT”
BUTTON
LCD
WINDOW
“BACK”
 BUTTON
SPEAKER
AWAY
 
Figure 1: External View