To stop the alarm, press 
 and then key in your 
valid user code. 
2.13 Disarming and Stopping Alarms 
Disarming the system stops the siren before it stops 
automatically, irrespective of whether the alarm was 
initiated in the armed or the disarmed state.  
After disarming, different displays may appear, depending 
on the current status of the system: 
A. 
Disarming - no events: After an uneventful armed 
term, the disarming operation will progress as shown: 
Action Resultant 
Display 
Sound 
 
 
C O D E          
_ _ _        
 y
 
[
³
]
 
 
R E A D Y           H H : M M
 
 
 y
 
 ARM indicator extinguishes 
B. 
Disarming after alarm, with all zones ready: If 
the zone that alarmed in the armed state is back to 
normal, the disarming operation will progress as shown: 
Action Resultant 
Display 
Sound 
 
 
C O D E          
_ _ _        
y
 
[
³
]
 
 
R E A D Y           H H : M M  
      (alternating)        
 
R E A D Y         M E M O R Y
 
 
 
 y
 
 ARM indicator extinguishes 
  To read the alarm memory, refer to Section 5. The 
"MEMORY"  message  will disappear only upon re- 
arming the system. 
C. 
Disarming after an alarm, with one zone still 
disturbed: If the zone that alarmed in the armed state 
is still disturbed, the disarming operation will progress 
as shown in the following table. 
Action Resultant 
Display 
Sound 
 
 
C O D E          
_ _ _        
 y
 
[
³
]
 
 
N O T   R E A D Y   H H : M M  
      (alternating)        
N O T   R E A D Y   M E M O R Y
 
 
 
 y
 
 ARM indicator extinguishes 
  To read the alarm memory, refer to Section 5. The 
"MEMORY"  message  will disappear only when you 
rearm the system.  
  If you do not know how to return the disturbed zone to 
normal, consult your installer. 
D. 
Disarming with the system in a state of 
trouble. If trouble is detected in the armed state, the 
TROUBLE indicator on the front panel will light and the 
disarming operation will progress as shown: 
Action Resultant 
Display 
Sound 
 
 
C O D E          
_ _ _        
 y
 
[
³
]
 
 
R E A D Y           H H : M M  
      (alternating)        
 
R E A D Y         T R B L
 
 
 
 y
 
 ARM extinguishes and 
 sounds once per minute 
  To find out what kind of trouble is being sensed, see 
Section 5. The TRBL display will disappear, the 
TROUBLE  indicator will extinguish and the trouble 
beeps will stop upon eliminating the cause for trouble. 
E. 
Disarming after an alarm, with the system in 
a state of trouble. The TROUBLE indicator on the 
front panel will light. If the zone that alarmed while the 
system was in the armed state is back to normal, the 
disarming operation will progress as shown: 
 
Action Resultant 
Display 
Sound 
 
 
C O D E          
_ _ _        
 y
 
[
³
]
 
 
R E A D Y           H H : M M  
      (alternating)        
 
R E A D Y         T R B L  
      (alternating)        
R E A D Y         M E M O R Y
 
 
 
 y
 
 ARM extinguishes and 
 sounds once per minute
To find out which zone alarmed and what kind of trouble 
is being sensed, see Section 5. The TRBL display will 
disappear, the TROUBLE  indicator will extinguish and 
the trouble beeps will stop upon eliminating the cause 
for trouble. The MEMORY message will disappear only 
upon rearming the system. 
F. 
Disarming under Duress.  If you are forcibly 
compelled to disarm the system, enter the default 
duress code (2580) or another code set by the installer. 
Disarming will take place normally but a silent alarm will 
be transmitted to the central station. 
2.14 Siren Behavior 
Continuously ON when initiated by a burglar zone or a 
24-hour zone, and when a user initiates a “panic alarm”. 
When initiated by a fire zone (smoke is detected) ON - ON - 
ON - pause - ON - ON - ON - pause - ........ and so on. 
If there is nobody around to disarm the system upon alarm 
and a zone remains "open", the siren will sound for the 
time duration set by the installer - then will stop. The strobe 
light keeps flashing until the system is disarmed.  
 
 
3. SPEECH AND SOUND CONTROL  
3.1 Speech & Sound Cont. Push-buttons 
The sound and speech-related functions offered by the 
PowerMax+ are controlled with the keypad, as detailed in 
the following list.  
 
Key 
Function 
  Increasing the loudness of spoken messages  
  Decreasing the loudness of spoken messages  
  disabling the loudspeaker 
  Recording a spoken message for other users of  
the alarm system 
  Listening to a recorded message left by another 
user of the alarm system 
  Enabling / disabling the chime function in chime zones 
3.2 Adjusting the Speech Volume  
The following diagram shows how to increase the loudness 
by clicking the <1> key (assuming that the volume was at 
minimum to begin with).