Visonic Inc. PWRMCOMPLETE ユーザーズマニュアル

ページ / 36
USER SETTINGS
 
22 
D-300886 
Bypassing Zones
Bypassing Zones
Bypassing Zones
Bypassing Zones    
A. General Guidance 
You can program the PowerMaxComplete to exclude 
(bypass) selected zones, regardless of whether 
these zones are "functional" (undisturbed) or "open" 
(disturbed). Bypassing permits free movement of 
people within certain zones although the system is 
armed. It is also used to temporarily remove from 
service faulty zones that require repair work. Fire 
zones can not be bypassed.  
Remember – zone bypassing compromises security! 
Zone bypassing must be carried out while the system 
is in the disarmed state. 
Note:  Zones will be bypassed throughout one 
disarm-arm period only. Disarming the system after 
arming will suspend the entire bypassing scheme, 
which can be recalled later, if so desired. 
B. Bypassing Procedure 
Having entered your user code successfully (see 
above - Entering to the User Settings Menu), the 
display will read: 
SET BYPASS 
If at this point you click 
, the number, 
state and name of the first zone will be automatically 
displayed. Three states are possible: 
• 
Open:  The zone is not secured - you can 
bypass it if you do not wish or know how to solve 
the problem just now. 
• 
Bypassed:  The zone is presently bypassed 
(you bypassed it before but haven't armed the 
system yet).   
• 
Functional: If there is nothing wrong with the 
zone, its state is described as "Functional".  
Let us assume that Zone 1 is "open" and you wish to 
bypass it, and the rest of the zones are functional. 
PRESS RESULTANT 
DISPLAY 
Z01: OPEN 
 
 
     (alternating)      
     
 
KITCHEN 
<OK> TO BYPASS 
 
Z01: BYPASSED 
 
 
     (alternating)        
 
KITCHEN 
Z02: FUNCTIONAL 
     (alternating)      
     
FRONT DOOR 
 
(If you wish 
to check the  
state of the 
next zone) 
 
 
SET BYPASS 
You can select any other item on the USER SETTINGS 
menu or quit programming by clicking 
. When 
<OK> TO EXIT is displayed - click 
.
 
After end of bypassing operation, BYPASS blinks:
 
READY BYPASS 
or 
NOT READY BYPASS 
This indication will persist as long as the system 
remains disarmed, and will disappear once the 
system is armed.  
Note: BYPASS will alternate in the display with other 
messages, like: TroubleMemory and Message
C. "Unbypass" Procedure 
Suppose you wish to restore a zone to service after 
having completed the bypassing scheme. Simply re-
enter the SET BYPASS menu (see Bypassing 
Procedure above), and click 
 or 
 until 
the zone you wish to "unbypass" is on display. Refer 
to the following steps. 
PRESS RESULTANT 
DISPLAY 
Z22: BYPASSED 
 
 
     (alternating)        
 LIVING 
ROOM 
<OFF> TO CLEAR 
 
Z22: FUNCTIONAL 
     (alternating)        
 
LIVING ROOM 
You may now click 
 and then select any other 
item on the USER SETTINGS menu, or click 
 
to quit programming. When <OK> TO EXIT appears 
- click 
Reviewing the Bypassed Zone List
Reviewing the Bypassed Zone List
Reviewing the Bypassed Zone List
Reviewing the Bypassed Zone List    
Having entered your user code successfully (see 
above - Entering to the User Settings Menu), the 
display will read:  
SET BYPASS 
Click 
 to change the display into: 
SHOW BYPASS 
Click 
 to change the display into: 
BYPASS LIST 
If at this point you click 
, the number, 
state and name of the first bypassed zone will be 
displayed.  
You can now click 
 repeatedly to review 
all bypassed zones, in ascending numerical order. 
When done, clicking 
 will get you back to 
SHOW BYPASS and clicking 
 will get you back 
to <OK> TO EXIT.