Visonic Inc. PWRMCOMPLETE ユーザーズマニュアル

ページ / 36
USER SETTINGS
 
26 
D-300886 
You may now review and select any other mode on 
the User menu (by clicking 
 or 
). 
Deleting Keyfob
Deleting Keyfob
Deleting Keyfob
Deleting Keyfob    
Occupied keyfob memory locations must be cleared 
(enrolled ID must be deleted) before enrolling a new 
ID. To delete an existing ID, proceed as follows: 
A.  Select the desired memory location, as described 
in the previous paragraph, steps A-C. If, for 
example, you selected keyfob No. 5, the display 
will read: 
Keyfob No.                  5 
 
B.  Click 
. The display will change to: 
<OFF> to delete 
C.  Click 
The display will change to: 
Keyfob No.                      5    
Note that the dark box at the far right has 
disappeared. It is now possible to enroll a new ID. It 
is also possible to leave the cleared zone or memory 
location free and simply exit to the main menu. 
Enrolling Proximity Tags (optional)
Enrolling Proximity Tags (optional)
Enrolling Proximity Tags (optional)
Enrolling Proximity Tags (optional)    
Valid proximity tags enable you to perform variety of 
functions without entering user code, for example, 
arming, disarming, reading the event log, etc. 
Whenever user code is required, you can simply 
present a valid proximity tag instead of entering user 
code.  
When the system is disarmed, after presenting a 
valid proximity tag to the control panel, the message 
"<OK> for AWAY" is displayed. Now you can press 
the 
 button to immediately arm the 
control panel, or wait for 3 second for system 
automatic AWAY arming (the message "Please exit 
now" will be displayed). Presenting the proximity tag 
once again will DISARM the system. 
Instead of pressing the 
  button (see 
above), you can press the 
 button once 
/ twice (the message "<OK> for HOME" / "<OK> for 
disarm" is displayed, accordingly) and then press the 
press 
  button for HOME arming / 
disarming.   
The control panel transmits an RF signal. A valid 
proximity tag that is presented to the control panel 
transmits a coded RF signal back to the control unit.  
Up to 8 proximity tags can be enrolled to the PM 
PRO.
Proximity tag enrolling involves the following steps: 
A. 
Having entered your Master User Code 
successfully (see Entering the User Settings 
Menu), Click the 
 button 
(repeatedly, if necessary) until the display will 
read:  
 
E N R O L L   P R O X   T A G
 
B. Click 
. The display will read: 
 
T a g   N o :       1  
C.  Click 
. The display will prompt you 
to initiate a transmission from the chosen tag: 
 
P R E S E N T   T A G  
D. Present the tag to the control panel left bottom 
side. In response, the “Happy Tune” (- - - –––) will 
sound and the display will change to: 
 
T a g   N o :       1  
 
 
A dark box will appear at the far right, indicating that 
the chosen tag has been enrolled. 
E. Click 
 and enroll the next proximity 
tag (2, 3,...8), as described in step D. 
F.  From this point on, you may continue in several 
different directions: 
• 
If you wish to enroll another tag, select the 
desired number by:   
- Clicking 
  
  
to go up 
 
(6
%7%8.....)   
- Clicking
 
 to go down (4
%
3
%
2.....) 
   
 
-   Clicking   
 
% <tag#>. 
• 
To return to the main menu, click  
. This 
will bring back the display: 
 
< O K >   T O   E X I T
 
You may now review and select any other mode on 
the User menu (by clicking 
 or 
). 
Deleting Proximity Tags
Deleting Proximity Tags
Deleting Proximity Tags
Deleting Proximity Tags    
Proximity tag memory locations must be cleared 
(enrolled ID must be deleted) before enrolling a new 
ID. To delete an existing ID, proceed as follows: 
A.  Select the desired memory location, as described 
in the previous paragraph, steps A-C. If, for 
example, you selected Tag No. 5, the display will 
read: 
T a g   N o .       5  
 
B.  Click 
. The display will change to: 
< O F F >   T O   D E L E T E      
C.  Click 
The display will change to: 
T a g   N o .       5