INNCOM International Inc. 202111TXR ユーザーズマニュアル

ページ / 10
E V O R A   D a t a s h e e t  
P a g e   8   o f   1 0
 
 
 
Load Specifications 
Single Gang Installation 
The following table provides the load ratings at absolute maximum based on the load type in a single gang wall box. 
Actuator 
Ratings 
 
Voltage 
Frequency 
Power / Amperes 
Load Type 
SMPS 
120-240Vac 
50/60Hz 
200mA  
+12VDC Output 
Only 
120-240 Vac 
50/60 Hz 
4.1 A 
Resistive 
120-240 Vac 
50/60 Hz 
4.1 A 
General Purpose 
120-240 Vac 
50/60 Hz 
500 W 
Tungsten / ELV 
120-240 Vac 
50/60 Hz 
250 VA 
Electric Ballast 
Relay Actuator 
120 Vac  
50/60 Hz 
1/10 HP 
Motor 
120 Vac 
60 Hz 
2.9 A 
Resistive 
120 Vac 
60 Hz 
500 W 
Tungsten / ELV 
120 Vac  
60 Hz 
250 VA 
Electronic Ballast 
TRIAC Dimmer 
120 Vac  
60 Hz 
1/10 HP 
Motor 
120 Vac 
60 Hz 
2.9 A 
Resistive 
120 Vac  
60 Hz 
2.9 A 
General Purpose 
120 Vac  
60 Hz 
350 W 
Tungsten / ELV 
MOSFET Dimmer 
120 Vac  
60 Hz 
250 VA 
Electronic Ballast 
120-240 Vac 
50/60 Hz 
7200VA 
General Purpose 
120-240 Vac 
50/60 Hz 
960W 
Tungsten / ELV 
120-240 Vac 
50/60 Hz 
800VA 
Electronic Ballast 
Master Contactor 
120-240 Vac 
50/60 Hz 
30A 
Resistive 
Class-2 Output 
The Load Assembly has been designed to provide +12VDC power to devices connected to the S5bus. The Load 
Assemblies can operate in parallel to supply a higher total load capacity than that achievable by a single Load 
Assembly. However, the total output is derated as per the table below for accommodating the stability of the 
power supply circuitry. The total available output power must be shared with the EVORA User Interface. Refer to 
the following table for Class-2 Output ratings. 
Number of Load 
Assemblies 
Nominal Voltage 
Voltage at Maximum 
Load 
Output Rating 
+12VDC 
+11.0VDC 
200mA 
+12VDC 
+11.0VDC 
375mA 
+12VDC 
+11.1VDC 
550mA 
+12VDC 
+11.1VDC 
660mA 
+12VDC 
+11.2VDC 
880mA 
+12VDC 
+11.2VDC 
990mA