Climax Technology Co Ltd DC9 ユーザーズマニュアル

ページ / 2
 
Door Contact (DC-9) 315M 
The Door Contact is used to detect the opening and closing of doors and windows.    Typically the Door Contact is fixed to 
the doorframe and the actuating magnet is fixed to the door.    When the door opens, the magnet is moved away from the 
Door Contact and an internal magnetic switch is activated causing the Door Contact to transmit an alarm. 
The Door Contact can monitor a doorway for open or closed status and notify you of an open door when you wish to arm 
your system.    It can also alert you to signal communication problems and low battery situations. 
The Door Contact consists of a two-part design made up of a cover and base.    The cover contains all the electronics and 
the base provides a means of fixing.    A PCB tamper switch protects the enclosure from being opened or being removed 
from the mounting surface. 
z
z
 
 
I
I
d
d
e
e
n
n
t
t
i
i
f
f
y
y
i
i
n
n
g
g
 
 
t
t
h
h
e
e
 
 
p
p
a
a
r
r
t
t
s
s
 
 
Remove the cover by loosening the bottom fixing screw, 
the inside of the Door Contact will be revealed as shown. 
LED indicator 
Test button 
Tamper Switch 
Extension Terminal 
JP 1 = Test / Normal Mode Jumper Switch   
If the jumper is ON (the jumper link is inserted connecting the two pins), the Door Contact is in Test 
mode. 
If the jumper is OFF (if the jumper link is removed or “parked” on one pin), the Door Contact is in Normal 
mode (factory default). 
JP 2 = Supervision Enable/Disable Jumper Switch   
If the jumper is ON (the jumper link is inserted connecting the two pins), the Supervision is disabled. 
If the jumper is OFF (if the jumper link is removed or “parked” on one pin), the supervision is enabled. 
(Factory default) 
JP 3 = Internal Magnet Switch Bypass Jumper Switch 
   
If the jumper is ON (the jumper link is inserted connecting the two pins), the internal magnet switch is 
being bypassed.    Only the device connected to the Extension Terminal will activate the Door Contact.     
If the jumper is OFF ( if the jumper link is removed or “parked” on one pin), the internal magnet switch is 
in use. (Factory Default) 
   
JP 4 = Reserved
 
z
z
 
 
L
L
E
E
D
D
 
 
I
I
n
n
d
d
i
i
c
c
a
a
t
t
o
o
r
r
 
 
 
 
In Normal operation mode, the LED indicator will not light except in the following situations: 
When the Door Contact is in Low battery condition, every time the Door Contact is activated (door opened or 
door closed), the LED will light. 
When the cover is opened and the tamper switch is violated, the LED will light. 
When the tamper condition persists, every time the Door Contact is activated, the LED will light. 
However, if the Door Contact is in Test mode, the LED will flash every time it is activated. 
z
z
 
 
B
B
a
a
t
t
t
t
e
e
r
r
y
y
 
 
 
 
The Door Contact uses one 1/2 AA, 3.6V Lithium battery as its power source.    The Door Contact will have a typical 
battery life of over 3 years at an average of 50 activations a day.  Please note to always replace battery with the 
correct size and voltage.   
Low battery detection operates at a threshold of 2.7V  ±5 % where the Door Contact has enough reserve power to 
typically operate for 1 month before complete exhaustion. When Door Contact is in low battery, the LED will flash and 
a low battery signal will be sent to the Control Panel along with regular signal transmissions for the Control Panel to 
display the status accordingly. 
z
z
 
 
S
S
u
u
p
p
e
e
r
r
v
v
i
i
s
s
o
o
r
r
y
y
 
 
S
S
i
i
g
g
n
n
a
a
l
l
 
 
(
(
w
w
h
h
e
e
n
n
 
 
t
t
h
h
e
e
 
 
J
J
2
2
 
 
i
i
s
s
 
 
O
O
F
F
F
F
)
)
 
 
z  After installation, the Door Contact will automatically transmit Supervisory Signals periodically to the Control 
Panel at intervals of 30 min to 50 min randomly. 
z
z
 
 
G
G
e
e
t
t
t
t
i
i
n
n
g
g
 
 
S
S
t
t
a
a
r
r
t
t
e
e
d
d
 
 
Remove the fixing screw and cover assembly   
Insert the “1/2 AA” battery into the battery holder taking care to connect the polarity correctly. 
The LED indicator will flash briefly, then, wait for 10 seconds.    It is then ready for operation in normal mode. 
z
z
 
 
M
M
o
o
u
u
n
n
t
t
i
i
n
n
g
g
 
 
M
M
e
e
t
t
h
h
o
o
d
d
s
s
 
 
There are two ways to mount the Door Contact, by either Self-adhesive installation or Screw mounting. 
Self adhesive mounting 
1
5
3
4
2
7
6
8