HD-9 is a heat detector with both rate-of-rise and fixed temperature sensors insides. It provides capacities of monitoring the 
rate of any rise in temperature and detecting a household temperature that may lead to a fire disaster. It is ideal for 
applications for the environment affected by heat, such as kitchen. 
The Heat Detector is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. 
Z-Wave is a wireless communication protocol that uses a low-power RF radio. By taking advantage of the Z-Wave mesh 
network, commands can be transmitted to their destination via intermediary “listening” Z-Wave products. 
HD-9 is designed to detect two temperature conditions. It signals an alarm if temperature increases by 8.3 °C per minute. 
The alarm is also activated if the temperature exceeds the threshold temperature of 57.3°C. The intelligent design allows 
appropriate action to be taken and eliminates fire hazards. 
 
 
1. Red LED 
z  When HD-9 is reporting an alarm, the LED will turn on for 1.5 seconds, and afterwards, the LED will flash until 
the temperature is restored. 
z  When the Heat Detector has low battery, the LED will flash once every 30 seconds (HD-9 will also emit a beep) 
z When 
the 
temperature sensor of HD-9 is out-of-order, the LED will flash once every 60 seconds (HD-9 will also 
emit a beep) 
z  During Alarm Silence period, the LED will flash once per second. 
2.Test Button 
z  Press 3 times within 1.5 seconds to transmit a learn code and HD-9 will emit a 2-tone beep 
z  Press once to test if the Heat Detector is functioning normally 
z  Press once to silence the alarm 
3. Battery compartment 
4. Mounting Hole 
5. Mounting Bracket  
 
z
z
 
 
B
B
a
a
t
t
t
t
e
e
r
r
y
y
 
 
z 3 
AA” Alkaline batteries are used to supply power. 
z  The Heat Detector will report its battery percentage to the Control Panel respectively at 100%, 75%, 50% and 
25%. If the battery voltage is low (25%), a Low Battery signal will be sent to the Control Panel to notify the user. 
z  When the Heat Detector is under low battery condition, a low battery signal will be transmitted along with 
regular signal transmissions. If the battery voltage is low, HD-9 will emit one beep and the LED will flash 
once every 30 seconds and inform the Control Panel regularly. 
<
<
N
N
O
O
T
T
E
E
>
>
 
 
When changing batteries, after removing the old batteries, press the Test button twice to fully discharge 
before inserting new batteries. 
 
z
z
 
 
A
A
d
d
d
d
i
i
n
n
g
g
 
 
D
D
e
e
v
v
i
i
c
c
e
e
 
 
(
(
I
I
n
n
c
c
l
l
u
u
s
s
i
i
o
o
n
n
)
)
 
 
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other 
manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters 
regardless of vendor to increase reliability of the network. 
z  Insert the 3 “AA” batteries into the battery compartment connecting the correct polarity as shown on the 
battery compartment lid. 
z  HD-9 will emit a 2-tone beep. 
z  Put the Z-Wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-Wave 
gateway or control panel manual).