Climax Technology Co Ltd SD16ZB ユーザーズマニュアル

ページ / 7
 
Smoke Detector   
SD-16-ZBS / SD-16SL-ZBS 
 
Introduction 
SD-16(SL)-ZBS is a ZigBee Smoke Detector. It is capable of sending wireless signals to the coordinator 
in the ZigBee network upon detection of smoke particles. The Smoke Detector is designed to be 
mounted on ceiling or top of stairwells when smoke would concentrate to raise alarm timely and protect 
your home from fire hazards. 
The Smoke Detector utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless 
communication protocol that is reliable and has low power consumption and high transmission efficiency. 
Based on IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network 
and coordinated for data exchange and signal transmission 
The Smoke Detector serves as an end device in the ZigBee network. It can be included in the ZigBee 
network to transmit signal upon activation, but cannot permit any other ZigBee device to join the network 
through the Smoke Detector.   
The SD-16 Series Smoke Detector includes following models, the models differ in battery used. 
SD-16ZBS 
SD-16SL-ZBS 
 
Parts Identification 
1. Red LED 
- Continuous quick flashes   
The Smoke Detector is alarming. 
- Two quick flashes   
The Smoke Detector has successfully joined a ZigBee network after 
factory reset. 
- Flashes once every 20 minutes: 
The Smoke Detector has lost connection to its current ZigBee 
network. 
- Flashes every 4 seconds: 
Battery Exhausted 
- Flashes every 2 seconds: 
The Smoke Detector is under warm-up and self-calibration process 
- Flashes every second: 
The Smoke Detector is in Alarm Silence mode. 
2. Amber LED 
- Flashes every 4 seconds: 
Battery Exhausted 
- Flashes every 5 seconds: 
Auto-calibration has failed. 
3. Function Button 
- Press the button once to send a supervision signal / test Smoke 
Detector 
- Press the button once during alarm to silence the alarm. 
- Press and hold the button for 10 seconds then release to reset the 
Smoke Detector. 
- Press and hold the button for 20 seconds then release to recalibrate 
the Smoke Detector. 
4. Buzzer 
5. 
Mounting Hole
 
The Hook of the Mounting Bracket can hook into this Mounting Hole.
 
6. 
Battery compartment
 
The battery used varies according to Smoke Detector model number. 
7. 
Battery Compartment Cover