Slim Door Contact (SDC-1) User Manual 
 
The Slim Door Contact monitors the opening/closing of specified devices (e.g. door or window). The Door Contact is fixed to 
the monitored device frame with an actuating magnet fixed to the device. When the door or window opens, the magnet 
moves away from the Door Contact, activating an internal magnetic switch causing the Door Contact to transmit alarm signal 
to the Control Panel. The device also has the capabilities of communicating signal problems along with low battery situations. 
 
Identifying the parts 
  
 
1. 
LED Indicator 
2. 
Learn/Test Button 
*(Use a sharp tool such as a paper clip to press the Learn/Test button). 
- Press the button to transmit a learn code. 
- Press the button once to enter Test Mode for 3 minutes. 
3. 
Magnet Detection Area 
4. 
Magnet 
- Please refer to Magnet Scope Positioning for how to use the magnet with the Door Contact correctly.
 
LED Indicator     
In Normal operation mode, the LED indicator remains off except in the following situations: 
 
When the Door Contact is activated under Low battery condition.
 
 
When the Door Contact is activated and transmitting the signal under the Test mode. 
 
Features 
 
Supervision   
 
The Door Contact will automatically transmit supervision signals to the Control Panel at random intervals of 
30 to 50 minutes in Normal Operation Mode. 
 
If the Control Panel has not received the signal from the Door Contact for a preset period time, the Control 
Panel will indicate that the Door Contact is experiencing an out-of-signal problem. 
 
Battery 
 
The Door Contact uses a pack of 10 x CR1616 battery as power source 
 
The Door Contact is also capable of detecting low battery condition. When the battery is low, a low battery 
signal will be sent to the Control Panel along with regular transmission. The LED will light up when the Door 
Contact is activated under low battery status.
 
<NOTE>
 
 
The pre-inserted battery in the Slim Door Contact cannot be replaced or switched out. 
 
 
Test Mode 
 
The Door Contact can be put into Test mode for 3 minutes by pressing the Learn/Test Button once.   
 
During Test mode, the LED indicator will light up upon triggering.   
 
Each press on the Test Button will lead the Door Contact to transmit a test signal to the Control Panel for 
radio range test and reset the test mode to the 3-minute duration.   
 
The  Door Contact  will  automatically  exit  Test Mode after  the  3-minute  duration  and return  to  Normal 
Operation mode.