Climax Technology Co Ltd SDF1 ユーザーズマニュアル

ページ / 4
 
S
S
m
m
o
o
k
k
e
e
 
 
D
D
e
e
t
t
e
e
c
c
t
t
o
o
r
r
 
 
(
(
S
S
D
D
-
-
1
1
6
6
U
U
L
L
)
)
 
 
z
z
 
 
G
G
e
e
n
n
e
e
r
r
a
a
l
l
 
 
I
I
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
 
 
Before installation of the Smoke Detector, please read through this instruction manual thoroughly to understand 
the Smoke Detector functions, responses and the guidelines to installing the Smoke Detector. 
Please leave this manual with the user of the Smoke Detector. 
 
z
z
 
 
G
G
e
e
n
n
e
e
r
r
a
a
l
l
 
 
D
D
e
e
s
s
c
c
r
r
i
i
p
p
t
t
i
i
o
o
n
n
 
 
The SD-16 Smoke Detector is a wirelessly operated photo-electronic smoke detector designed to operate with the 
VST-2700 series, the M Series and the HPGW Series Climax wireless Control Panels. The Smoke Detector’s 
alarm situations, battery condition, operating conditions, supervisory data and general fault information are sent to 
the Control Panel wirelessly. 
The Smoke Detector calibrates for the air contents after warming up to determine a standard condition for the 
environment. It can be manually instructed to calibrate for air content. It is also pre-programmed to automatically 
calibrate once a month. 
When the Smoke Detector is triggered, a Smoke Alarm Signal is transmitted to the Wireless Control Panel. The 
built-in buzzer will start a local alarm siren of 85dB (in compliance with the UL Standard 217) and the Red LED will 
flash quickly for 10 seconds as a local warning. The Smoke Detector will continuously check the smoke 
concentration and turn the local warning on every 10 seconds if smoke concentration does not drop below the set 
value. The alarm signal is transmitted every 2 minutes until the smoke condition is cleared to reset the Smoke 
Detector. The local alarm siren will also continue to siren if the alarm signal is continuously being sent every 2 
minutes. The test button of the Smoke Detector can be pressed to silence the alarm for 10 minutes. When the 
smoke condition is reset, a smoke alarm restore signal is sent to the Control Panel. 
The condition of the Smoke Detector will be sent to the Control Panel every 30 to 50 minutes as a supervisory 
signal. 
Mounting the Smoke Detector is simplified with the mounting bracket, where the mounting bracket is fixed to the 
surface using screws and dowels. The Smoke Detector is then fixed to the mounting bracket by hooking itself onto 
the mounting bracket. 
 
z
z
 
 
I
I
d
d
e
e
n
n
t
t
i
i
f
f
y
y
i
i
n
n
g
g
 
 
t
t
h
h
e
e
 
 
P
P
a
a
r
r
t
t
s
s
 
 
 
 
 
1. Red LED 
When the battery voltage is low, the Red LED will flash every 45 sec. 
While the Smoke Detector is transmitting a signal, the Red LED will turn on. 
After the battery is inserted and the Smoke Detector is in warming and calibration process, the Red LED will flash 
once every 2 seconds for 2-7 min.   
2. Yellow LED 
When auto calibration (1 calibration per month) fails, the yellow LED will flash once every 5 seconds. 
3. Test Button 
Pressing the Test Button to: 
z  Transmit a radio signal for learning-in the Smoke Detector. 
z  Transmit a radio signal for testing the radio communication range. 
z  Test if the Smoke Detector is functioning normally. 
z  Silence the Smoke Detector’s alarm 
4. Buzzer 
When the Smoke Detector is triggered, the buzzer will start a local alarm of 85dB (in compliance with the UL 
Standard). One local alarm cycle is of the pattern: 
0.5 second beep, 0.5 second silence, 0.5 second beep, 0.5 second silence, 0.5 second beep, 1.5 second silence. 
The cycle is repeated continuously.