Climax Technology Co Ltd SVGS ユーザーズマニュアル

ページ / 4
SVGS-1ZBS Shock, Vibration & Glass break sensor 
SVGS-1ZBS is a ZigBee Shock, Vibration/Glass Break Sensor. It is capable of sending wireless signals to the coordinator in the 
ZigBee network upon detection of window glass break or shock vibration detection. 
The Sensor utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless communication protocol that is 
reliable and has low power consumption and high transmission efficiency. Based on the IEEE 802.15.4 standard, ZigBee allows 
a large amount of devices to be included in a network and coordinated for data exchange and signal transmission. 
The Sensor serves as an end device in the ZigBee network. It can be included in the ZigBee network to transmit signal upon 
activation, but cannot permit any other ZigBee device to join the network through the Sensor. 
 
Parts Identification
    
1.  Function Button 
Using sharp tools such as paper clip to press and hold the Function Button for 10 
seconds to send learning signal to the Control Panel / or Reset to factory 
settings. 
2.  LED Indicator 
The LED indicator lights up in the following conditions: 
LED flash Once: The Sensor has been reset. 
LED flash Twice: The Sensor has successfully joined ZigBee network. 
 
Features 
 
 
 Battery and Low Battery Detection 
 
The Sensor use one CR2032 3V Lithium battery as its power source. Please note: ALWAYS replace battery with the 
correct size and voltage. 
 
The Sensor can detect if the battery is low. When the Battery is low, a low battery signal will be sent to the Control 
Panel along with regular transmission. 
 
When changing battery, use a sharp tool to open the battery slot to remove and insert battery. 
 
When  inserting  batteries,  the  positive(+)  side  of  the  battery  must  face  upward.  NEVER  insert  the  battery  with 
negative(-) side facing upward. 
 
 
 
 
 
 Supervision 
The
 
Sensor will transmit a supervision signal to report its condition regularly according to the user’s setting. The factory 
default interval is 30 minutes. The user can also press the Function Button once to transmit a supervision signal manually. 
 
 Sensitivity 
The Sensor can send alarm signal to the Control Panel according to different sensitivity levels set in the Control Panel. 
The Sensitivity levels include high, medium, and low (default is medium), the higher the sensitivity the easier to trigger the 
Sensor when window/glass break or shock vibration detected. 
 
Please use sharp tools such as a paper clip and to press the Sensor’s function button once. The Sensor will wake up 
(for 1 minutes) and send test signal to the Control Panel before setting sensitivity. 
 
Start setting sensitivity level on the Control Panel (Please refer to your Control Panel for details).