Climax Technology Co Ltd TS9 ユーザーズマニュアル

ページ / 2
 
1
T
T
e
e
m
m
p
p
e
e
r
r
a
a
t
t
u
u
r
r
e
e
 
 
S
S
e
e
n
n
s
s
o
o
r
r
 
 
(
(
T
T
S
S
-
-
9
9
E
E
L
L
)
)
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
TS-9EL is a temperature wireless sensor device. It transmits temperature condition to the Control 
Panel every 30 minutes. 
 
 
 
I
I
d
d
e
e
n
n
t
t
i
i
f
f
y
y
i
i
n
n
g
g
 
 
t
t
h
h
e
e
 
 
p
p
a
a
r
r
t
t
s
s
 
 
Remove the cover by loosening the bottom fixing screw using a Philips screwdriver, the inside 
of the Temperature Sensor will be revealed as shown. 
1.  Temperature Switch 
Press this switch to send status information to the 
Control Panel. 
2.  Internal LED 
Flashes 3 times –when pressing the Learn/Status 
Button. 
Flashes every 4 seconds – Battery exhaustion 
3.  Learn/Status Button 
Pressing the switch will send out a learn code. The 
status information is also transmitted to inform the 
control panel the status of the Temperature Sensor. 
4.  Battery Compartment 
5.  Internal Temperature Probe 
 
 
  Battery 
The  Temperature  Sensor  uses  one  CR123  -  3V  Lithium  battery.  Please  always  replace 
battery with the correct size and voltage. 
When  the  Temperature  Sensor  is  low battery,  a  low  battery  signal  will be sent  to  the  Control 
Panel  along  with  regular  signal  transmissions  for  the  Control  Panel  to  display  the  status 
accordingly. 
When the battery is depleted, the LED flashes every 4 seconds and the Temperature Sensor 
will stop all functions. 
 
Battery Change 
I.  Remove the Cover by loosening the bottom fixing screw using a Philips screwdriver. 
II.  Remove the Old Battery. 
III.  Press the Temperature Switch or the Learn/Status Button a few times. 
IV.  Fit a new battery into the battery compartment. Please orient the battery according 
to the correct polarity. 
V.  Replace the Cover and lightly tighten the bottom fixing screw using a Philips 
screwdriver. 
 
 
  Getting Started 
Step 1  Remove the base and cover assembly by loosening the bottom fixing screw using a 
Philips screwdriver. 
Step 2  Insert the battery into the battery holder taking care to connect the polarity correctly. 
Step 3  Put  the  Control  Panel  into  learning  mode.  Please  refer  to  your  Control  Panel  user 
manual. 
Step 4  Press Learn/Status Button to send learn code to Control Panel. 
Step 5  Refer to the user manual of the Control Panel to complete the learn-in process. 
Step 6  To check for range, put the Control Panel into range test mode (or Walk Test mode). 
Please refer to the control panel user manual. Conduct the range test of the Control 
Panel by pressing the Learn/Status Button of the Temperature Sensor.