560A 18
 
+ 12 V 
Ignition Key In Sensor 
Switch Closes with Key In 
Ignition Cylinder 
Drivers Door Pin Switch 
87a 
86 
30 
87 
85 
Key In     
Chime Module 
Connected to (-) Negative 
Safety Input Wire   
White/ Black (H6/4
To Hood Pin Switch    Safety 
Shut Down (H6/4
1N4003
+ 12V 
 
 
To connect to the key in sensor as shown in method 1: 
A.  Locate the control wire that connects the drivers door pin switch to the key in sensor switch. 
B.  Cut this wire and connect the ignition cylinder side to chassis ground. 
C.  Locate the key in sensor switch wire that connects the chime module to the ignition cylinder. 
D.  Cut this wire and connect the ignition cylinder side to terminal 30 of a P&B VF45F11 or equivalent relay. 
E.  Connect the cathode (striped) side of a 4003 series diode to this same wire, and connect the (non striped) 
side to the negative safely input wire (WHITE/ BLACK) (H6/4) of the Remote Start Unit. 
F.  Connect terminal 86 of the relay to a fused + 12 volt constant battery source. 
G.  Connect terminal 87 of the relay to the Chime Module side of the previously cut wire in step D. 
H.  Connect terminal 85 of the relay to the Drivers Door side of the pin switch wire previously cut in step B. 
Note: A second 4003 series diode may be required to maintain the integrity of the hood open, shut down 
circuit.    If this is the case, it must be installed as shown in the diagram above. The anode (Non Stripped) 
side must be connected to the WHITE/ BLACK wire (H6/4) of the Remote Start Unit. The cathode (Striped) 
side must be connected to the hood pin switch.     
METHOD 2 
 
Ignition Key In Sensor 
Switch Closes with Key 
In Ignition Cylinder 
Connected to (-) Negative 
Safety Input Wire   
White/ Black (H6/4
To Hood Pin Switch   
Safety Shut Down (H6/4)
1N4003 
 
To connect to the key in sensor circuit as shown for method 2: 
A.  Locate the control wire that connects the drivers door pin switch to the key in sensor switch. 
B.  Cut this wire and connect the ignition cylinder side to chassis ground. 
C.  Locate the key in sensor switch wire that connects the chime module to the ignition cylinder. 
D.  Cut this wire and connect the ignition cylinder side to the Remote Start Negative Safety Shut down wire 
WHITE/ BLACK (H6/4), using a 4003 series diode as shown above. 
Note: A second 4003 series diode may be required to maintain the integrity of the hood open, shut down 
circuit.    If this is the case, it must be installed as shown in the diagram above. The anode (Non Striped) side 
must be connected to the WHITE/ BLACK wire (H6/4) of the Remote Start Unit. The cathode (Striped) side 
must be connected to the hood pin switch.   
AFTER THE CONNECTION OF THE NEUTRAL START SAFETY WIRE AS INDICATED IN ANY OF THE 
PREVIUOS ALTERNATE CONFIGURATINS, THIS CIRCUIT MUST BE TESTED FOR OPERATION. 
Retest by following the steps outlined in the NEUTRAL START SAFETY TEST shown in this manual.       
 
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions. 
(1)This device may not cause harmful interference, and 
(2)This device must accept any interference received, including interference that may cause undesired 
operation. 
 
Per FCC 15.21, you are cautioned that changes or modifications not expressly approved by the part 